DUPLICATING AND ENABLING REMOTE CONTROLS
The system is supplied with two remote controls and can accept up to a maximum of 6.
You must go to an authorised Aprilia service centre for this service: remember to take your CODE CARD
with the 16-digit alpha-numerical code with you.
Your Aprilia service centre will order a new, pre-programmed remote control for you (it is essential to have
the code shown on the Code Card). The customer or the Aprilia service centre can then pair up the new
remote control, as described in the following procedure:
CAUTION: YOU MUST HAVE ANY EXISTING REMOTE CONTROLS ON HAN
IN ORDER TO COMPLETE THIS PROCEDURE CORRECTLY
Automatic pairing procedure:
1) Disarm the system using the remote control or by entering the OVERRIDE code.
2) Switch the instrument panel on (+15) three consecutive times within 3" until you see the LED is lit without
flashing and hear an acute buzzer sound;
3) Enter the OVERRIDE code (see the EMERGENCY DISARMING VIA THE OVERRIDE CODE section)
and leave the key in the ON position (+15) after the fifth digit.
If you have entered the correct code, the alarm system will emit two acute buzzer sounds (beeps) followed
by two flat sounds (boops), confirming you have accessed the procedure.
4) Press the button on the new remote control until the alarm system LED lights up;
5) Press the button on the new remote control again and check that the LED now goes off followed by an
acute buzzer sound: the alarm system has now stored the new remote control into its memory.
Repeat steps 4 and 5 to store all the remote controls you want the alarm system to recognise.
NB: This also includes any existing remote controls.
Exit the procedure by turning the key to the OFF position. The alarm system will now emit two acute buzzer
sounds (beeps) and two flat sounds (boops) by way of confirmation.
NB: every time you take the key out of the ignition, the Led will flash the same number of times as the remote
controls paired up with the system.

BATTERY BACK UP

The alarm system has its own integrated batteries and will trigger an alarm if its cables are cut or the vehicle's
battery is disconnected.
If the battery connection is restored, the alarm will stop sounding 30" after it has been reconnected.
The battery back up safeguards up to 9 alarm cycles, sounding for 26" with a 15" pause.
The direction indicators do not operate when the alarm is operating on its battery back up supply. The battery
back up is only operational when the alarm has been armed.
If the vehicle's power supply has been disconnected, the buzzer will sound during the entry phase to warn
you and continue until the end of the entry phase. Afterwards, the alarm signal will continue with a dual tone
sound.
THE E52 REMOTE CONTROL
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
pag. 12

Publicidad

Tabla de contenido
loading

Productos relacionados para APRILIA Meta System

Tabla de contenido