Festo DPA Serie Instrucciones De Utilizacion página 20

Ocultar thumbs Ver también para DPA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
DPA
Connect the tubing to the supply ports as per Fig. 3.
S
With an output pressure greater than 10 bar, make sure that the permitted
limits for the connecting elements used at output 2 are observed (if
necessary connect the tubing to the DPA).
DPA−40
Fig. 3
Type
Connection number
Pneumatic connection 1/2
Tightening torque
Inner hose diameter/
recommended hose
type
type
20
1
2
3
DPA−40
1
Pneumatic connection 1 for input pressure
2
Pneumatic connection 2 for output pressure
3
Pneumatic connection 3 for exhaust air
3
M7
1/2
15 Nm
3
2 Nm
1
7 mm/
PAN−10x1.5
2
5 mm/
PAN−R−8x1.25
DPA−63/100
DPA−63
Gy
Gy
25 Nm
25 Nm
12 mm/
PAN−16x2
10 mm/
PAN−R−16x3
1
3
2
DPA−100
40 Nm
40 Nm
12 mm/
PAN−16x2
10 mm/
PAN−R−16x3
Festo DPA 0712d English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dpa-40 serieDpa-63 serieDpa-100 serie

Tabla de contenido