Descargar Imprimir esta página

Service Records - COZY 90N30A Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para 90N30A:

Publicidad

Idiomas disponibles

Idiomas disponibles

CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
For proper operation, Floor Furnace must be kept clean. At regular
intervals tum control valve to off, let cool, remove register and clean
dust and foreign material from jacket with vacuum cleaner.
Have the Floor Furnace checked by a qualified service technician for
venting system, pilot, and burner operation prior to its use each year.
Follow a regular service and maintenance schedule for safe and
efficient operation.
Keep flammable materials away from floor furnace area.
Be sure not to obstruct combustion and ventilation air.
TO CLEAN BURNER
1.
Remove bottom pan from outer casing.
2.
Remove 2 screws from burner support bracket.
3.
Remove 2 screws from pilot bracket allowing burner to slide off of
manifold and out of floor furnace.
4.
Examine the burner. If any distortion is noticed, replace burner.
5.
Clean burner ports by inserting a toothpick in ports to remove any
debris that might have accumulated.
6.
Inspect burner for spider webs or dust buildup during the off-season.
If necessary, wash out with garden hose.
7.
Re-install and adjust burner.
MAINTENANCE
Repair service must be performed by a qualified
service technician. The floor furnace must be inspected
before initial use. An annual cleaning of floor furnace
and safety performance check should be made by a
qualified service technician. More frequent cleaning
may be required when exposed to the excessive lint
conditions due to carpeting and bedding material, etc.
It is imperative that the control compartment, burners,
and circulating air passageways of the floor furnace
be kept clean. Any safety screen or guard removed for
servicing the floor furnace must be replaced prior to
operating heater.
Examine the entire venting system as a routine part of
the safety performance check on an annual basis.

SERVICE RECORDS

Page 15
!
WARNING:
DO NOT USE ANY KIND OF SOLVENT OR
CLEANING FLUID TO CLEAN YOUR FLOOR
FURNACE. IT MAY LEAVE A RESIDUE OR
INVISIBLE COATING THAT WILL BURN OR
SMELL WHEN YOU TURN YOUR FLOOR
FURNACE ON. USE ONLY A DAMP CLOTH.
!
WARNING:
THIS IS A GAS-FIRED FLOOR FURNACE.
KEEP THE AREA CLEAR OF GASOLINE
AND OTHER FLAMMABLE VAPOR AND
LIQUIDS. ALL COMBUSTIBLE MATERIAL
MUST BE KEPT CLEAR OF THIS AREA TO
AVOID FIRE OR EXPLOSION.
Back to Index