Your floor furnace and drafthood are packed together in one master carton. The carton containing the floor furnace also
contains the thermostat, thermostat wire, insulated staples, furnace key and lighter rod. The drafthood is packed in its own
carton within the master pack and contains screws and rope-like gasket material for attaching and sealing the draft hood to
the floor furnace. Check the model numbers on the two cartons to be sure they match.
MODEL NUMBERS
Gas Type
Height
Width
Length
Input (BTU / HR)
Gas Inlet
Vent Size / Wall Opening
Overall Grille Size
Size of Floor Opening
Floor to Center Line of Vent
Approximate Weight

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED FLOOR
FURNACE THAT WILL OPERATE SAFELY AND PROVIDE
AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED,
OPERATED AND MAINTAINED AS RECOMMENDED IN
THESE INSTALLATION AND OPERATING INSTRUCTIONS.
READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLING, SERVICING, OR USING THE APPLIANCE.
IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS, CONSULT LOCAL AUTHORITIES, OTHER
QUALIFIED INSTALLERS, SERVICE TECHNICIANS, THE
GAS SUPPLIER OR THE MANUFACTURER.
HELPFUL INSTALLATION INFORMATION
Do not attempt to heat through more than one doorway in any
direction to adjoining rooms.
Always over-estimate the amount of heat required rather
than under-estimate it. Always use the next size floor furnace
above your actual heating requirements.
Seal all cracks around windows, doors, and attic access
doors or significant heat loss will occur.
SPECIFICATIONS & DIMENSIONS
90N30A
Natural
29-1/4"
14"
32"
30,000
1/2"
4"
16" x 34-1/8"
14-1/4" x 32-1/4"
22"
108 lbs
Listed below are steps that are part of a floor furnace
installation. You must see that each step is followed closely
so that the floor furnace will provide maximum efficiency with
safe operation.
YOU MUST:
1. Locate the floor furnace in the best available
2. Provide fresh air for combustion and venting.
3. Cut and frame the floor opening so that the
4. Attach the draft hood and connect the vent
5. Connect an adequate gas supply to the floor
6. Select the best location for the thermostat.
7. Check and adjust the floor furnace for safe
If you have any doubts about the correct way to install a
floor furnace, contact local authorities or agency, or your gas
supplier. If local or state codes require that your floor furnace
installation be inspected by local authorities, do so after the
floor furnace is installed and before it is put into service.
Page 3
90N50A
Natural
29-1/4"
22"
32"
50,000
1/2"
4"
24" x 34"
22-1/2" x 32-1/2"
22"
126 lbs
INSTALLATION REQUIREMENTS
space for safe and efficient operation.
floor furnace fits properly.
pipe in compliance with applicable codes.
furnace.
and efficient operation.
Back to Index
90N65A
Natural
29-7/8"
24"
38"
62,000
1/2"
5"
26" x 40"
24-1/2" x 38-1/2"
22"
152 lbs
1017826-A

Publicidad

Capítulos

loading

Este manual también es adecuado para:

90n50a90n65a