If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
The ICM does not
work.
The ICM does not
cool.
The ICM does not
cool.
The ICM makes
noise.
There is water on
the floor.
The lights don't
work.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
Type of ICM
Serial number of the ICM
Brief description of the problem / observation
7

First aid

In case of accident, it is recommended:
ACCIDENT
Inhalation of refrigerant
Contact with eyes
Contact with skin
8

Disposal of the unit and packaging

For detailed information regarding the recycling of this product and its packaging, please contact your
local city office, your waste disposal service or the manufacturer through its service agent. By ensuring
14
POSSIBLE REASONS
Power cord not plugged in.
No power supply at the socket.
The ICM has recently been reloaded
with warm products. It takes some time
to cool warm products down.
The ICM is loaded in such a way that
the air circulation in the interior is getting
blocked.
Icing formation on the evaporator.
Leakage in the cooling system.
Intense metallic noise.
Damaged outer panels.
The drainage hole for the condensate
water is blocked.
There is a leakage in the tray.
The lighting or the transformer are out of
order
IMMEDIATE ACTION
Take deep breaths of clean air. If irritation persists, contact a doctor.
Wash your eyes thoroughly with plenty of water for at least 15 minutes
and then consult a doctor.
Wash immediately with water.
HANDLING
Plug it in.
Check the outlet fuse.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Call a Service technician.
Repair the leakage (this type of repair
should be performed by an authorised
technician).
Call a Service technician.
Call a Service technician.
Call a Service technician.
Call a Service technician.
Call a Service technician.