Interface Adjustments; Programming - golmar IT-4N Manual De Instalación

Interfaz telefónico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INTERFACE ADJUSTMENTS

D
escription of the dip switches:
The telephone interface has two dip switches beside the operation LEDs, which the installer can
access and configure without having to open the cover:
Dip switch 1:
O
*
OFF: Normal mode.
Ü
ON: Divert mode always enabled.
Ü
Dip switch 2:
O
*
OFF: No function.
Ü
ON: Changes the PIN to the factory standard.
Ü
*
Factory default.

PROGRAMMING

Programming the interface:
This unit needs to be programmed so as to configure the adjustable parameters of the system to
O
the needs of the user and the installation
With the system in standby, access the programming mode by picking the handset up of the
O
telephone and entering the PIN with the telephone keypad using the following sequence:
"##0 + PIN".
Ü
Once the programming mode is accessed, the programming sequence will be done by fields. See
O
the table on page 51.
To verify the state of programming, and if the sequence is correct or not, the handset's
O
speaker will emit the following tones:
Programming mode accessed: Five short tones.
Ü
Correct field code: Two medium-duration tones.
Ü
Correct code value: Four medium-duration tones.
Ü
Error: One long-duration tone.
Ü
To ensure a correct programming of the system, calls should not be made from either the audio
O
door entry system or from the telephone line while in programming mode.
If no keys are pressed during one minute the system will save the entered data and exit the
O
programming mode.
When finished, exit the programming mode by replacing the handset.
O
The adjustments will be automatically saved.
O
.
49

Publicidad

Tabla de contenido
loading

Tabla de contenido