GE PGS960 Serie Instrucciones De Instalación
Ocultar thumbs Ver también para PGS960 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation Instructions
Range
Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit
GEAppliances.com. In Canada, call 1.800.561.3344 or visit GEAppliances.ca.
IN THE COMMONWEALTH
OF MASSACHUSETTS
■ This product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION
HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the
current Propane Installation Code, CAN/CGA-
B149.2, and with local codes where applicable.
This range has been design-certified by
CSA International according to ANSI Z21.1,
FOR YOUR SAFETY:
WARNING
Tip-Over Hazard
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at
no cost. (In Canada, call 1.800.561.3344.) For
installation instructions of the bracket,
visit: GEAppliances.com.
(In Canada, GEAppliances.ca.)
■ When using ball type gas shut-off valves,
they shall be the T-handle type.
■ A flexible gas connector, when used, must
not exceed 5 feet.
latest edition and Canadian Gas Association
according to CAN/CGA-1.1 latest edition.
When installing a gas appliance the use of
old flexible connectors can cause gas leaks
and personal injury. Always use a NEW
flexible connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be
in accordance with the current CSA C22.1
Canadian Electrical Code Part 1 and/or local
codes. See Electrical Connections in this section.
Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
Anti-Tip Bracket
Kit Included
WARNING
Before beginning
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting
means cannot be locked, securely
fasten a prominent warning device,
such as a tag, to the service panel.
TOOLS YOU WILL NEED
Phillips
screwdriver
Open-end or
adjustable wrench
Flat-blade
screwdriver
Pencil and ruler
Level
Pipe wrenches (2)
Drill, awl or nail
(one for backup)
BEFORE YOU BEGIN
IMPORTANT —
Save these
instructions for local inspector's use.
IMPORTANT
— Observe all governing
codes and ordinances.
IMPORTANT
— Remove all packing
material and literature from oven before
connecting gas and electrical supply to range.
IMPORTANT
— To avoid damage
to your cabinets, check with your builder
or cabinet supplier to make sure that the
materials used will not discolor, delaminate
or sustain other damage. This oven has been
designed in accordance with the requirements
of UL and CSA International and complies
with the maximum allowable wood cabinet
temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these
instructions with consumer.
Note to consumer – Keep these instructions
for future reference.
Servicer – The electrical diagram is in an
envelope attached to the back of the range.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is
not covered under warranty.
Before installing your range on linoleum or
any other synthetic floor covering, make sure
the floor covering can withstand 180°F without
36 1/4" ± 1/4
shrinking, warping or discoloring. Do not install
the range over carpeting unless a sheet of
1/4" thick plywood or similar insulator is placed
between the range and carpeting.
MATERIALS YOU MAY NEED
■ Gas line shut-off valve
■ Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural
and propane gases
■ Flexible metal appliance connector (1/2" I.D.).
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new range.
■ Flare union adapter for connection to gas
supply line (3/4" or 1/2" NPT x 1/2" I.D.)
■ Flare union adapter for connection to pressure
regulator on range (1/2" NPT x 1/2" I.D.)
■ Liquid leak detector or soapy water.
*Teflon: Registered trademark of DuPont
Mobile Home - Additional Installation
Requirements
The installation of this range must conform
to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile
Home Construction and Saftey, Title 24,
HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A
or with local codes.
In Canada, the installation of this range must
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.
When this range is installed in a mobile
home, it must be secured to the floor during
transit. Any method of securing the range
is adequate as long as it conforms to the
standards listed above.
CAUTION
Only the GE Café
branded series of Advantium
®
over-the-range ovens are designed to
be installed above the GE Café range.
Surfaces above a gas range can become
hot. Installation of any other over-the-range
oven above a GE Café range may result in
surface temperatures that can cause burns.
1 1/8"
DOUBLE OVEN
Rating plate
or microwave

Publicidad

Tabla de contenido
loading

Resumen de contenidos para GE PGS960 Serie

  • Página 1 Phillips tape with Teflon* that resists action of natural screwdriver and propane gases Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit ■ Flexible metal appliance connector (1/2” I.D.). Open-end or A 5-foot length is recommended for ease of GEAppliances.com. In Canada, call 1.800.561.3344 or visit GEAppliances.ca.
  • Página 2: Dimensions And Clearances

    DIMENSIONS AND DIMENSIONS AND CLEARANCES (CONT.) flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015” [.38 mm] CLEARANCES GAS PIPE AND ELECTRICAL OUTLET LOCATIONS thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper. Provide adequate clearances between the range and adjacent combustible surfaces.
  • Página 3: Gas Supply

    To prevent gas leaks, put pipe joint compound Where a standard two-prong wall receptacle is GAS SUPPLY ELECTRICAL on, or wrap pipe thread tape with Teflon* encountered, it is the personal responsibility and around, all male (external) pipe threads. obligation of the customer to have it replaced with CONNECTIONS WARNING a properly grounded three-prong wall receptacle.
  • Página 4 Quality of Flames CHECK SURFACE LEVEL THE RANGE Determine the quality of flames visually. Normal BURNERS burner flames should look like (A) or (B). WARNING Never completely Push and turn a knob to the LITE position. A remove the leveling leg as the range will not clicking sound indicates proper operation of (A) Soft blue flames—...
  • Página 5: En El Commonwealth De Massachusetts

    ■ Sellador para junta de tubería o UL – cinta para Destornillador Philips tubería aprobada con Teflón*, resistente a la acción ¿Preguntas? Llame a GE Appliances al 800.GE.CARES (800.432.2737) o visita de gases naturales o propano GEAppliances.com. En Canadá, llame 1.800.561.3344 o visita GEAppliances.ca.
  • Página 6: Dimensiones Y Espacios

    DIMENSIONES Y ESPACIOS metálica de 28 MSG (.015” (.38 mm) de grosor), DIMENSIONES Y ESPACIOS (CONT.) .015” (.38 mm) de grosor de acero inoxidable, .025” Deje el espacio adecuado entre la cocina y las UBICACIONES DE LA TUBERÍA DE GAS Y DEL TOMACORRIENTE ELÉCTRICO (0.64 mm) de aluminio o .020”...
  • Página 7: Suministro De Gas

    Para evitar pérdidas de gas, coloque el compuesto En caso de contar con un tomacorriente de pared de SUMINISTRO DE GAS CONEXIONES ELÉCTRICAS de la junta de gas, o envuelva la cinta para roscas de 2 cables, es la responsabilidad y obligación del cliente tuberías con Teflón* alrededor de todas las roscas de reemplazarlo por un tomacorriente de pared de 3 ADVERTENCIA...
  • Página 8: Controle Las Cabezas De Los Quemadores

    Calidad de las Llamas CONTROLE LAS CABEZAS NIVELACIÓN DE LA COCINA Determine la calidad de las llamas de forma visual. DE LOS QUEMADORES Las llamas normales de los quemadores se deberán ADVERTENCIA ver como (A) o (B). Nunca retire Presione y gire la perilla a la posición LITE (Luz). Un completamente las patas niveladoras, ya que la sonido de clic indica el correcto funcionamiento del cocina no estará...

Este manual también es adecuado para:

Jgss86 serie

Tabla de contenido