Pfister Marielle LF-026-3N Guia De Inicio Rapido página 3

Grifo monomando con rociador lateral y dispensador de jabón
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7
7 CONTROL BODY INSTALLATION
Apply plumber's putty into groove on bottom of Gasket (7A) per manufacturer's
recommendations. Place Gasket (7A) under base of Control Body (7B). From above
sink, insert Threaded Shank (7C) and Flexible Tubing (7D) through side hole of sink.
8
8D
8 SECURING CONTROL BODY
From underneath sink, place Washer (8A), and Locknut (8B) onto Mounting Shank (8C).
Make sure Handle (8D) is facing forward and it swings equally in both directions. Tighten
Locknut (8B) firmly to Shank (8C).
Caution: Do not over tighten!
7B
7C
7A
7D
8C
8A
8B
ENGLISH
9
9A
9B
9 HOSE GUIDE & SOAP DISPENSER GUIDE INSTALLATION
Insert Hose Guide Shank (9A) through Flange Gasket (9B) and insert Soap Dispenser
Guide Shank (9C) through Foam Gasket (9D) and into the sink holes. If desired, place
a small bead of plumber's putty to the underside of Flanges (9A & 9C). (Both Hose Guide
and Soap Dispenser Guide can be placed in either hole).
10
10A
10C
10 SECURING HOSE GUIDE & SOAP DISPENSER GUIDE
From underneath sink, secure Hose Guide (10A) and Soap Dispenser Guide (10B) by
screwing Plastic Locknuts (10C) and (10D). Thread on Bottle (10E) to Soap Dispenser
Shank (10F). Hand tighten.
Caution: do not over tighten!
3
9C
9D
10B
10F
10D
10E