FIG. 3: Control Panel
A
C
Power ON/OFF
Solution pressure pump ON/OFF
Auto pumpout ON/OFF
7. Turn on VAC.
8. Turn on solution pump.
9. If using the auto-pumpout feature, press the auto-
pumpout switch (Fig. 3) to the On position.
10. Begin cleaning. Refer to industry-approved
procedures.
11. Solution pressure may be adjusted with the pressure
regulator knob (Fig. 2H). Monitor the pressure gauge
to ensure pressure is adequate.
12. If not using the auto-pumpout feature, use the
gravity drain with diverter in place to empty waste
when tank is full (Fig. 7).
CAUTION: When the recovery tank reaches capacity,
an automatic float valve blocks vacuum intake (Fig.
5) and the vacuum motors will make a high pitched
noise. When this occurs, the machine should be
FIG. 4: Solution inlet filter cleaning
07-02233B MANUAL - 1200MS 115V PORTABLE
B
D
E
F
G
Remove
nut with
9/16 in.
wrench
and lift
open top.
turned off immediately to prevent damage to the
vacuum motor.
13. When cleaning is completed, rinse solution tank with
clear water to ensure no detergents or rinse agents
remain in the tank.
14. Empty and rinse the waste tank thoroughly. This will
help to prevent the formation of damaging deposits
and reduce the growth of odor-causing bacteria. Use
gravity drain to drain waste tank when full. Attach
diverter to direct flow downward (Fig. 7).
15. Turn on vacuum motor and allow it to run for 15
minutes to help remove any moisture from the
vacuum motors and help ensure long vacuum life.
MAINTENANCE
WARNING: Unplug machine before servicing.
Possibility of electrical shock.
WARNING: Interior components may be hot
after operation. Let unit cool completely
before servicing.
DAILY OR AFTER EACH USE
Clean the solution inlet filter (Fig. 4) Loosen tank
attachment screw (Fig. 1) and open unit. Remove filter
cover and strainer screen (Fig. 4). Rinse strainer screen
clean in warm water. Replace strainer and retighten filter
cover.
Clean vacuum ball float valve (Fig. 5). Empty recovery
tank, then open recovery tank lid. Grasp valve assembly
and pull gently toward the front of the unit, taking care
not to distort the strainer screen. Rinse assembly clean
and make sure float ball moves freely inside assembly.
Clean recovery tank strainer (Fig. 6, pumpout models
only). Remove strainer by gently rotating it and lifting
upward. Rinse filter clean with water and reinstall.
Reinstall strainer and vacuum ball float valve assembly
securely.
AS NEEDED
Lubricate pressure regulator O-ring (if equipped).
Access O-ring by unscrewing and removing pressure
regulator knob (Fig. 2H). Lubricate with a suitable O-ring
lubricant.
Unscrew
inline filter
cap assembly
and remove.
4
Rinse cap
and filter
assembly
clean and
reinstall.