Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61

FIRST STORAGE OF TAGS

The XTR B must be in standby. The memory must
be empty.
1. Press and release the button once.
- After 2 s, the XTR B will BEEP once and flash once.
- It will flash for 20 s (storing enabled).
2. Bring the first Tag up to the reader.
- The XTR B will BEEP once and the LEDs will come
on for 2 s: the Tag is enabled.
- Flashing will resume for 10 s (storing enabled).
3. Repeat step 2 for any additional Master Tags
required.
4. To finish, let 10 s pass without bringing any
new Tags up to the reader (or press the button
immediately).
- The LEDs turn off: XTR B in standby.
Errors during storage process
During step 1, the XTR B signals
an error and turns off in standby:
the button has been pressed
more than once
During step 1, the XTR B signals
an error and turns off in standby:
the memory is not empty
During step 3, the XTR B signals
an error, then the LEDs turn off:
the Tag has not been stored
ERROR warning: Five BEEPS and 5 flashes
in quick succession.
XTR B
Solution
Repeat the pro-
cess correctly
Carry out the "Add
1+ 2 s: Tag OK ,
Tag" or "Total De-
letion" process
Carry out the "Add
Tag" process
6
FIRST STORAGE PROCEDURE
SW2
1
 2 s 1( ) ,
...  20 s MAX
2
First Master Tag
...  10 s MAX
3
Additional Master Tags
1+ 2 s: Tag OK ,
 timeout without Tag:
4
SW2
20 s ( timeout)
10 s ( timeout)
10 s  timeout
END
532109 - Rev.A

Publicidad

Tabla de contenido
loading

Tabla de contenido