Promax PROWATCH TELMO Manual De Instrucciones página 44

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

[4]
RF input
RF input , spiral F Female connector, 50 Ω. The RF work range is between
— 15 dBm and — 45 dBm, the typical value is — 20 dBm. This input is protected
from signals lower than 10dBm.
[5]
6 Warning Alarms (Alarms of low priority or warnings).
The equipment has six alarms of low priority or warnings and corresponds with
each of the multiplex that are being monitored. When one of these alarms has
been activated it means that an error could happen due to the measured levels
are going down. When a warning is detected the corresponding LED lighted up
and the associate relay changed its state.
The Warnings could be activated :
All these alarms will be activated when one of the previous points exceeds the
fixed limit. This limit will be selected by the user and could be modified at any time
using the control and configuration software. (For more detail go to the SW
installation and operation)
6 Fault Alarms (Alarms of high priority).
The equipment has six faults of high priority or Alarms and corresponds with each
of the multiplex that are being monitored. When one of these alarms has been
activated means that an error has happened due to the measured levels exceed
the fixed limits. When an Alarm is detected the corresponding LED lighted up and
the associate relay changed his state.
The Alarms could be activated :
All these alarms will be activated when one of the previous points exceeds the
fixed limit. This limit will be selected by the user and could be modified at any time
using the control and configuration software. (For more detail go to the SW
installation and operation)
Page 12
-
Nominal value (dBm) ( gone down )
-
VER post-Viterbi value
-
MER (dB) level.
-
Nominal value (dBm), ( gone down )
-
VER post-Viterbi value
-
MER (dB) level.
USER'S MANUAL. PROWATCH
TELMO
03/2008

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido