INDEX
1. APPLICATIONS ........................................................................................................................................... 1
2. PUMPABLE LIQUIDS .................................................................................................................................. 1
3. TECHNICAL DATA AND LIMITATIONS OF USE ...................................................................................... 1
4. MANAGEMENT ............................................................................................................................................ 2
4.1
Storage ................................................................................................................................................ 2
4.2
Transport ............................................................................................................................................... 2
4.3
Weight and dimensions ....................................................................................................................... 2
5. WARNINGS .................................................................................................................................................. 2
6. INSTALLATION ........................................................................................................................................... 2
7. ELECTRICAL CONNECTION ...................................................................................................................... 3
8. START-UP .................................................................................................................................................... 3
9. PRECAUTIONS ............................................................................................................................................ 3
10.2 Cleaning the impeller ............................................................................................................................ 4
11. TROUBLESHOOTING ............................................................................................................................... 4
12. GUARANTEE ............................................................................................................................................. 4
WARNINGS
Read all this documentation carefully before installation:
Take out the plug before any intervention. Absolutely avoid dry operation: the pump must be
activated exclusively when it is immersed in water. If the water is finished, the pump must be
deactivated immediately, taking the plug out of the socket.
The pump is equipped with a thermal overload safety device. In the event of any overheating of the
motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20
minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is
essential to identify and deal with the cause of the overheating. See Troubleshooting.
1. APPLICATIONS
Powerful multistage submersible pump ideal for rainwater systems, operating sprinklers, pumping water from cisterns,
tanks, ponds and other applications that require high pressure. Anti-corrosive and dust proof materials, overload
protection, wear resistant shaft, anti-debris stainless steel strainer, excellent cooling of the motor allowing the pump to
run even if partially submerged, automatic start/stop function with floating switch. Supplied with non-return valve and
4-step fitting.
These pumps cannot be used in swimming pools, ponds or basins where people are present, or for
pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the
accident prevention regulations in force. They should be cleaned before putting them away. See the
chapter "Maintenance and Cleaning".
2. PUMPABLE LIQUIDS
Fresh water
Rainwater
Clear waste water
Dirty water
Fountain water
River or lake water
Max. particle dimension [in]
Suitable
Not suitable
o
3. TECHNICAL DATA AND LIMITATIONS OF USE
Supply
voltage: 115-120V, see electrical data plate
Delayed line fuses
Storage
temperature: 14 F - 104 F
(115-120V
version): indicative values (Ampere)
ENGLISH
o
o
Ø 0.04
1
Table1