FES-200 W3
Proceed as follows:
Fig. 2 Functional description on page EN-12
1 Put the fume extraction system on the floor.
2 Switch off the fume extraction system by turning the rocker switch (11) (0 position).
3 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
4 Remove the suction hose from the air intake fitting (6).
5 Close the air intake fitting (6) with the seal plug supplied (7).
6 Connect the compressed air.
Fig. 4 Filter dedusting on page EN-14
7 Open the valve lever (4) on the compressed air connection.
Due to the compressed air, the cleaning nozzle rotates inside the fine filter cartridge. By moving the tube
manually upwards and downwards, the exhaust fume deposits are completely removed from the filter and
the filter is refreshed. The separated dust is collected in the dust collecting drawer.
8 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
9 Remove the knurled nuts (9) from the dust collecting drawer (8).
10Carefully pull out the dust collecting drawer (8).
11 Put the separated dust from the dust collecting drawer (8) into the dust collecting bag supplied and close
it.
5.1 Emptying the dust collecting drawer on page EN-13
NOTICE
• The dust collecting drawer (8) must be emptied before and after each dedusting of the filter.
• If the dedusting of the filter has no effect on the suction power, the filter must be replaced.
5 Functional description