2 2
SYSTEM CONFIGURATIONS
INSTALLATION GUIDE
If you have added components to your Water Conditioner,
note the correct sequencing below.
WITH A POST FILTER AND UV
PRE-FILTER*
(Recommended)
WATER
CONDITIONER
TANK
WITH A WATER SOFTENER
PRE-FILTER*
(Recommended)
WATER
CONDITIONER
TANK
*Due to the varieties of home design, not all installation configurations can be addressed in this guide.
NEED HELP? GIVE US A CALL 833.232.9711
POST-FILTER*
(Optional)
UV*
(Optional)
WATER
SOFTENER*
POST-FILTER*
(Optional)
PRECAUTIONS AND MAINTENANCE
AOW-FC600
Rated service flow 7 gpm (26.5 Liters)
Max capacity 600,000 gallons (2,271,247 Liters)
Min working pressure 20 psi (137.9 kPa)
Max working pressure 100 psi (689.5 kPa)
Min operating temperature 40° F (4.44° C)
Max operating temperature 90° F (32.22° C)
Read all precautions and installation
instructions carefully and completely
before installing.
The exterior of your filtration system
can be cleaned with warm, soapy water.
Rinse well with fresh, clean water. Never
use chemical cleaning products on the
system's exterior surface as they may
damage the housing.
A sediment pre-filter for your system
is recommended. Sediment levels vary
from one location to another. If the flow
rate has noticably decreased, a pre-filter
to remove the sediment is usually the
root cause. If you have a pre-filter, once
the flow rate has noticeably decreased
it is time to replace the filter. Allowing
sediment to collect continuously can
cause clogging and restrict the flow of
water into your home. We recommend
replacing your sediment pre-filter
UV*
cartridge every 2-3 months.
(Optional)
Precautions
• Do not install this filter where the
line pressure may exceed 100 psi. The
operating pressure range for this filter
is between 20psi – 100psi.
• Install on cold water lines only
(40° – 90°F). Protect unit
from freezing.
• Unit must be installed in an area
where the main water line enters your
home, before connecting to the water
heater. DO NOT install after the water
heater or on the hot water line.
• Do not install the unit on its side. It
must be installed upright to maximize
contact with media bed.
• It is recommended your system be
installed inside and out of direct
sunlight. If this is not possible and
the system is installed outdoors or in a
sunny area, the unit must be
protected from both direct sunlight
and freezing temperatures.
• Installation of the filter must comply
with existing state and local plumbing
codes. A. O. Smith is not liable for
consequential or incidental damages
due to improper installation.
• Improper sequence of equipment will
affect performance, and could possibly
damage your system.
NEED HELP? GIVE US A CALL 833.232.9711
3