INSTALLATION GUIDE
INSTALLATION GUIDE
Remove red shipping caps
1
from the inlet and outlet
ports on the main housing.
2
Pre-condition the unit by surge flushing. It's imperative that this system is flushed
properly prior to final installation. The granular carbon medium used in the bottom
tank contains 1-2% by volume of carbon fines that must be flushed out prior to use.
Surge flushing is the best method for purging these carbon fines from the media bed.
1
Using the supplied adapter,
connect a garden hose to
the inlet port so the water
will flow into the system
and out of the outlet port.
3
After an initial 15-minute flushing, begin
a period of "surge flushing" by turning on
water supply for 30 seconds and then
off for 30 seconds, repeating cycle for
15 minutes or until initial surge of water
is completely clear and free from
discoloration and cloudiness.
Turn off the main water
3
source prior to installation.
Pick an appropriate installation
4
location. Unit must be installed in
an area where the main water line
enters your home, before it connects
to the water heater. DO NOT install
after the water heater or on the
hot water line. Components and
installation will vary.
Do not over-tighten fittings, as this may cause leakage and broken fittings. Do NOT use
pipe dope. The use of pipe dope voids the warranty. You may use NSF-certified pipe
primer, glue and plumber's tape. Leave 2 or 3 threads exposed and do not exceed seven
layers of plumber's tape. More than seven layers will cause the nipple to crack and leak.
NEED HELP? GIVE US A CALL 833.232.9711
IMPORTANT Keep the unit in an upright
position at all times.
2
Slowly turn on faucet and allow
discolored water to flow from
outlet into a suitable drainage
area. The first few gallons will
appear black and cloudy due to
carbon fines.
4
Disconnect the system
from the garden hose
and position it for
final installation.
IMPORTANT
The inlet piping assembly must be firmly braced and supported.
Once installation is complete, slowly
5
turn on water and inspect for leaks.
Once the unit is installed and checked
6
for leaks, turn on the faucet closest
to the installed unit and allow water
to run for 5-10 minutes for the final
flushing period.

PERFORMANCE DATA SHEET

INSTALLATION GUIDE

CARE AND MAINTENANCE

Performance Data Sheet for the A. O. Smith Water Conditioner
Models
Replacement
Max operating pressure Rated capacity
AOW-FC600
100 psi (689.5 kPa)
600,000 gallons
AOW-FC600
(2,271,247 liters)
Manufactured by: A. O. Smith Corporation 11270 West Park Place | Milwaukee, WI 53224 | 833.232.9711
Testing was performed under standard laboratory conditions, actual performance may vary*. Filter usage must comply with all state and local laws.
Filter is only to be used with cold water. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. Not
all contaminants listed may be present in your water. Filter does not remove all contaminants that may be present in tap water. See owner's manual
for general installation conditions and needs as well as manufacturer's limited warranty. Do not use with water that is microbiologically unsafe or of
unknown water quality without adequate disinfection before or after the system.
DATA SUMMARY TABLE
Accumulated
Dynamic Pressure (psi)
Volume (gal)
Sample
Point
Effluent 1
Influent
Startup
150
61
10%
60,000
61
20%
120,000
60
30%
180,000
60
40%
240,000
60
50%
300,000
60
60%
360,000
61
70%
420,000
60
80%
480,000
61
90%
540,000
61
100%
600,000
61
System Tested and Certified by NSF International
against NSF/ANSI Standards 42 for the reduction
of Chlorine taste and odor as specified on the
performance data sheet and at www.nsf.org.
For use with municipally treated water only. Do not use with water that is
microbiologically unsafe or of unknown water quality without adequate
disinfection before or after the system.
Operating temp. range Rated flow
40-90° F
7 gpm
4.44-32.2° C
(26.5 lpm)
Chlorine, Free Available
Flow Rate (gpm)
(mg/L)
Influent
Effluent 1
Effluent 1
2.2 ND(0.05)
ND (0.05)
7.1
2.2 ND(0.05)
ND (0.05)
7.0
1.9 ND(0.05)
ND (0.05)
7.0
2.2 ND(0.05)
ND (0.05)
7.0
2.1 ND(0.05)
ND (0.05)
7.0
2.1 0.05
0.05
7.0
2.1 ND(0.05)
ND (0.05)
7.1
2.2 0.09
0.09
7.1
1.9 ND(0.05)
ND (0.05)
7.1
2.0 ND(0.05)
ND (0.05)
6.9
2.0 0.18
0.18
7.1