Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters 10,000 Btu/Hr or more shall not
be installed in a bedroom or bathroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See Air
Combustion and Ventilation
for
7 through 9. If heater keeps shutting off,
Troubleshooting
see
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
MODEL
Ignition
Gas Type
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Gas Type
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Dimensions (HxWxD) 19
Carton Dimensions (HxWxD)
Heater Weight
Shipping Weight
4
SAFETY
, pages
, page 22.

SPECIFICATIONS

MD2TPA
Electric Piezo
Natural Gas
12,000
6" W.C.
Maximum 10.5"
Minimum 7"
Propane Gas
10,000
10" W.C.
Maximum 14"
Minimum 11"
/
" × 14
/
" × 7
1
1
8
8
22 ×16
/
" × 8
3
7
4
15.1 lbs
18.1 lbs
www.usaprocom.com
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
8. Always run heater with control knob at
PILOT/IGN, LOW (1) or HIGH (5) locked
positions. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
9. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off and unplug heater and let cool
before servicing. Only a qualified service
person should service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lbs. capacity.
MD3TPA
Electric Piezo
Natural Gas
20,000
6" W.C.
Maximum 10.5"
Minimum 7"
Propane Gas
18,000
10" W.C.
Maximum 14"
Minimum 11"
/
" 23
/
" × 19
/
" × 8
1
1
1
8
2
4
/
"
25
/
" × 21
/
" × 10" 25
3
3
8
4
4
21.6 lbs
25.6 lbs
MD5TPA
Electric Piezo
Natural Gas
30,000
6" W.C.
Maximum 10.5"
Minimum 7"
Propane Gas
30,000
10" W.C.
Maximum 14"
Minimum 11"
/
" 23
/
" x 26
/
" x 8
3
1
5
4
2
8
/
" x 28
/
" x 10"
3
1
4
2
28.1 lbs
33.1 lbs
200042-01A
/
"
3
4

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Md3tpaMd5tpaMd3tpa-bbMd5tpa-bb

Tabla de contenido