Fagor SCT 8000 Manual Del Usuario página 12

Transmodulador dvb s / s2 dvb-c free-to-air / common interface
Ocultar thumbs Ver también para SCT 8000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.1. Save Configuration:
Stores current programming.
7.2. Restore Configuration:
stored in the unit to be recovered.
7.3. Save Configuration, Device to UCF 300:
enables the configuration stored to be saved with an
identifying name in one of the 26 memories of the
UCF 300.
7.4. Load Configuration, UCF 300 to Device:
ecovers the data in one of the UCF 300's memories
with data recorded from an STT for cloning on another
STT 8000.
RF LEVEL ADJUSTMENT
1.
Remove the coaxial bridge from the RF channel
output (8) of module 1 beside the power source.
2.
Adjust the output level to 75 dBμV via UCF 300
(see point 2 Programming).
3.
Connect the 75 Ω axial bridge again.
4.
Taking the measurement at the SHA or SAC amplifier
output, adjust the levels of the other modules so that
they are equalised to the level of module 1,
which has already been adjusted.
5.
Adjust the amplifier gain, taking into account its
maximum output level and the reduction according
to the number of the channels in the installation,
as shown in Table 1.
Tab. 1
Number of
2 4
channels digital
Reduction of the
maximum output
3 6
level (dB)
LED FUNCTIONS
Status LED:
Green color: Tuner tuned
Yellow color: Signal problems
– Unsyncronized tuner.
– Program not found.
– Exceeded output BW > 92%.
– Out RF: OFF.
Red color: Unit failure
Communication LED: Yelow: waiting for data.
Enables the configuration
5
6
8 16 24 32 64
7
8
9 12 16 15 18
12