Board
ATTENTION: DANGEROUS TENSIONS.
During the sound, voltages of more than
300 V peak-to-peak are present at the
output supplying the siren loudspeaker
Do not touch the electronics with bare hands while
playing, especially the conductive parts, connec-
tors and conductors in the vicinity of the voltage
transformer.
If action is to be taken, take appropriate precautions
as required by the regulations.
HIGH VOLTAGE Do not remove the label that secures the points in which they develop dangerous voltages.
OUT SIR.
Connector connection siren Cone
+ - BATT
Connection Back-up battery 12 V - 1,2 or 2,3 Ah
+ - CHARGE
Connection external power supply with nominal tension 14,5 V =
ALIM.
Connection Connector battery Pack of 4 alcaline batteries type D
TAMPER
Connection Connector Tamper
FLASH
Connection Connector FLASH
S1
1 - 2: Setting with external power supply kit - mod. ALCITYWS4
2 - 3:
S2
Do not modify - Internal use
Installation
1
Remove the outer (main) cover
6
Turn the Tamper into
position, as shown
Setting with use of battery Pack of 4 alcaline batteries type D
2
Use the bottom of the
siren to set the 3
wall mounting holes ...
4
Use a drill 8mm
to make the four holes
Battery holder type SIZE D.
To be removed with the use
of the mod. ALCITYWS4
Insert the cover of the
battery in the bottom of
the column and push
down
In special installations, to
avoid falling batteries, use
the flanges to fix the cover
to the bottom
OUT
SIR.
3
2
1
7
Thanks to the initial Cone and Flash block,
the power supply can be connected.
8
Perform the acquisition procedure with the
control panel
9
Close the cover.
- 7 -
ALIM.
TAMPER
3
For placement
correct the siren,
use the bubble in
equipment
5
Attach the bottom of the
siren to the wall with 3
dowels
During the commis-
sioning phase and in
subsequent mainte-
nance, it is possible
to place the external
cover (as shown in
the figure at the side)
on the polycarbonate
base.
E
N
G