INSTALLER PROGRAMMING

TEP 3I
STEP 1I - Press NEXT and ▲ simultaneously for 3 seconds.
STEP 2I – Hardness: Set the amount of influent hardness using ▲ or ▼.
This display will not be shown if FILTER is selected in Step 2F OR if oFF
TEP 2I
or a number was selected in Step 8S. Press NEXT to go to step 3I. Press
REGEN to exit Installer Display Settings.
STEP 3I – Hardness 2: If using a mixing valve, set the amount of effluent
hardness using ▲ or ▼. Range of available values may vary depending on
system capacity selected and hardness selected in Step 2I. This display
will not be shown if FILTER is selected in Step 2F OR oFF or a number
was selected in Step 8S. Press NEXT to go to Step 4I. Press REGEN to
return to previous step.
STEP 4I – Day Override: When volume capacity is set to oFF, sets the
number of days between regenerations. When volume capacity is set to
AUTO or to a number, sets the maximum number of days between
regenerations. If value set to oFF, regeneration initiation is based solely on
volume used. If value is set as a number (allowable range from 1 to 28) a
regeneration initiation will be called for on that day even if sufficient volume
of water were not used to call for a regeneration. Set Day Override using
▲ or ▼:
 number of days between regeneration (1 to 28); or
 OFF
See Setting Options Table for more detail on setup. Press NEXT to go to
step 5I. Press REGEN to return to previous step.
STEP 5I – Next Regeneration Time (hour): Set the hour of day for
regeneration using ▲ or ▼ buttons. The default time is 2:00. This display
will show "REGEN on 0 m
Option in OEM Softener System Setup or OEM Filter System Setup.
Press NEXT to go to step 6I. Press REGEN to return to previous step.
STEP 6I – Next Regeneration Time (minutes): Set the minutes of day for
regeneration using ▲ or ▼. This display will not be shown if "on 0" is
selected in Set Regeneration Time Option in OEM Softener System Setup
or OEM Filter System Setup. Press NEXT to exit Installer Display Settings.
Press REGEN to return to previous
step.
To initiate a manual regeneration immediately, press and hold the REGEN
button for three seconds. The system will begin to regenerate immediately.
The control valve may be stepped through the various regeneration cycles
by pressing the REGEN button.