WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 MasterCool® Mirage Evaporative Window Cooler Operating and Installation Instructions Congratulations on your purchase of the MasterCool® WPL44 /WPL44NP plastic evaporative cooler. This unit is manufactured with the intent of offering you years of reliable, efficient cooling. NOTE: READ THESE INSTRUCTIONS BEFORE INSTALLING THE COOLER. Follow the installation instructions in this manual carefully. Varying from them may create safety concerns and will void the warranty. Safety Instructions Use only with 110V 60 Hz single phase grounded outlet. Ensure cooler is turned OFF and UNPLUGGED before installing, servicing or cleaning the unit. Do not operate unit with damaged cord or plug, or with any other damaged or missing parts. o not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Note About Evaporative Coolers : Ventilation: Unlike traditional air conditioners, evaporative coolers require an open ventilation system, not a closed system. Both a fresh air source and an exhaust opening are required to provide correct air flow. Typically, a partially opened window or door in each room where cooling is desired will create correct airflow for optimum effectiveness of an evaporative cooler. NOTE: For best results, open windows/doors should not be on the windward side on the house. Water bleed or purge: Evaporative Coolers require a continuous supply of water to keep the media saturated for maximum cooling. Water pumped into the cooler must be removed from the unit to ensure mineral and bacteria build‐up do not occur. This can occur with a gravity‐fed steady bleed off stream or a timed purge system via a pump. CAUTION: Water expelled from the cooler must be routed away from any areas that could do damage to foundations or other vulnerable areas. Features of the MasterCool® Mirage Window Cooler This cooler’s housing and frame are made of heavy‐duty U‐V resistant plastic to provide a light weight, easily installable cooler. The unit is constructed in two basic sections to facilitate quick installation into traditional ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 INSTALLATION PROCEDURES WARNING: Do not connect electrical power to the unit until the installation is completed. NOTE: The MasterCool Mirage window cooler can be installed in a sash‐style or a slider‐ style window. Clearances required: Width: 22”; Height: 22”. A 4” clearance above the exterior cabinet is needed for maintenance. NOTE: Ensure the location selected for installing the unit is strong enough to support the unit and will accept the mounting hardware. The operating weight of the cooler is 93 pounds. NOTE: A minimum of two people are required to install this window cooler. Parts Included: Cooler Unit Window Sill Mounting brackets (2) Accordion spacers (2) Hardware kit Tools & Materials Required: Drill (power or cordless) Assorted drill bits (for drilling pilot holes for mounting hardware) Adjustable Wrench Phillips Head Screwdriver Silicone or all‐weather caulk for sealing infill panel to window frame Length of ¼” copper or plastic tubing Silcock valve Bubble level Cooler Installation Remove unit from box. Verify that all parts are included. 1. Remove all packing materials. CALL 1‐800‐643‐8341 IF YOU FIND PARTS MISSING OR HAVE ANY QUESTIONS 2. With the unit in an upright position, pull the fan assembly forward (about 6”) until it is fully engaged with ...
Página 5
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 3. Remove screen and make sure window is opened to its Cooler Installation (con’t) maximum height. From the exterior of the window, slide the fan assembly section into the window. Have the person on the interior adjust the exact placement of the unit for aesthetics and correct lengths of the two accordion spacers (included). Note: After identifying the position for installation, place a bubble level on top of the unit and make adjustments to ensure the unit will be level when installation is complete. It is recommended to verify unit is level at various points during installation. 4. Closing the window may help hold the unit in place during the following steps – Push the unit into the window until the bottom is flush with the outside wall or pre‐installed spacer (when necessary) as shown in the illustration. 5. Make sure unit is level. From the interior, locate the two tracks on the bottom of the fan assembly. Drill pilot holes as necessary and install the two window sill brackets as shown in illustration. 6. From the outside, secure the unit to the exterior wall (or spacer) with two screws at the base of the back cover (as shown in illustration.) Complete the installation of the exterior portion with two screws at the top of the back media guard. 7. With the unit now installed in the window, attach one accordion spacer to each side of the fan assembly using the adhesive backed edges. Short screws can be used for a more secure installation. (Make sure screws do not interfere with fan blade) 8. Once accordion spacers are installed, seal any gaps around the units with silicone or all weather caulk. ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Water Connection NOTE: A standard sill cock with water valve attached (locally available) will be required to connect the water supply to the cooler. 1. Steady water supply is required for operation of the cooler. If taking water from an external water faucet, install a sill cock and shutoff valve. 2. Install plastic or copper line to sill cock and connect it to the float valve. Water Pump A self‐contained water pump continuously circulates water through the water distribution system and over the media. This pump is rated for 7500 CFM supplying more than adequate water pressure to saturate the media for cooling effectiveness. Overflow Drain Slide the rubber washer over the overflow fitting and push through the hole in the bottom of the cooler from the top side. Secure the drain from beneath the pan with the Lock Nut. Make sure the rubber washer does not twist while tightening, which could cause it to leak. DO NOT OVERTIGHTEN. If leakage occurs after reservoir is full, retighten the overflow fitting until leaking stops. A small amount of silicone caulk may be used if necessary. ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Electrical System The electrical system does not require general maintenance. The following wiring diagram is supplied for reference only. Purge Pump (Installed on WPL44 only) In addition to the standard water pump to recirculate water from the reservoir, the WPL44 has a purge pump that is programmed to evacuate the contents of the reservoir every 6 hours. This helps retard bacterial growth and mineral buildup on the media, extending its life. It also maintains fresher air in the home. The use of the purge pump is actually more economical to use than a continual bleed line. DO NOT DISABLE THE PURGE PUMP. WPL44NP NOTE : A purge pump can be installed on the WPL44NP unit to convert it into a WPL44. Order Purge Conversion Kit, part number 72314 which includes pump, mounting bracket, hose assemblies and mounting hardware. Purge Pump Discharge NOTE: The water ejected at the time of purging will be expelled at a high rate of speed, and must be routed away from the foundation of the home or other areas where rushing water could do damage. 1. Attach a standard water hose to the overflow drain to direct the water way from the house. NOTE: This water is not potable, but can be used for watering vegetable or flower gardens. 7 ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 OPERATING INSTRUCTIONS The WPL44 has an electronic touch control panel in the upper right hand corner. Before turning unit on, ensure unit is plugged in, water supply to pump is on, and there is correct ventilation, as shown on page 4 of this manual. Note: These units may be controlled using the 3 buttons on the front panel of the cooler or with the remote control. On/Off This button initiates power to the unit. When first plugged (or after a power failure), pressing ON/OFF will start the unit in the default setting (pump ON and Fan on HIGH). After its initial use, the last operating settings (for fan and pump) will be reinstated when the unit is turned on again. Pressing this button when the unit is already running will turn both fan and pump off. Pump This button toggles the pump on and off. When the LED is lit, the pump is running. The pump must be on while operating the fan for the unit to operate as an evaporative cooler, though the unit can be used in fan mode without the pump, if desired. Note: For best results turn on the pump for a few minutes to wet the pads before operating the fan. Fan Pressing the fan button cycles the unit from HIGH, to MEDIUM to LOW speeds and then OFF. Please Note: There is a two second delay from the pressing of the button for the fan to engage or change speeds. This applies to the front control panel and the remote control. Remote Control The remote control supplied with this cooler allows you to turn the unit on or off, control fan speed and initiate the pump. The buttons operate in the same manner as those on the front control panel. The remote control’s range is approximately 20 feet within sight of the ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 USER SERVICING INSTRUCTIONS Maintenance on evaporative coolers is minimal, but very important to the proper operation and effectiveness of your cooler. Periodic inspection of the cooler’s interior will reduce the potential for substandard cooling due to insufficient or uneven water distribution. NOTE: For general maintenance purposes, the unit may be rapidly drained of water by removing the overflow fitting from the bottom of the unit. This is not adequate draining for winterization (see procedures under Winterization section.) Annual Maintenance (May be Needed More Often in Areas with Hard Water) Cleaning WARNING: Disconnect from electrical power and turn unit off during all maintenance. Turn water supply off before removing back for cleaning or maintenance. 1. Remove the back media guard (as shown below). 2. Inspect pads in place. Remove media pads from back guard by unscrewing the media peg clips. Be careful not to chip or damage the media while removing. Visually inspect both sides of media pads. Look for blockage, mineral build‐up or mildew growth, breakage or other anomalies. 9 ...
Página 10
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 3. Wash pads with a garden hose. Do not use a pressure washer. 4. Check water distributor for blockage or excessive buildup of dust. 5. Set media in a safe place until all maintenance is complete. 6. Wash out reservoir thoroughly using a soft bristle brush. Use plenty of water and a white vinegar solution, if necessary, to remove algae growth. Clean areas around pump, strainer and float to ensure no algae growth remains. CAUTION: Do not use harsh chemicals to clean the interior portions of the cooler. Do not use abrasive cleaners on the exterior of the cooler body to maintain its UV resistance. 7. Rinse thoroughly after using any cleaning solutions have been used on the interior or exterior of the unit. Water System Pump: 1. The water pump is a self‐contained unit that should require no maintenance other than ensuring that no debris or corrosion interferes with free movement of the parts. 2. Ensure hose connection to pump is in good condition. Water Float: 1. The float level is factory set for optimum performance, however moderate adjustments can be made by bending the float arm for a different water level. 2. The maximum recommended water level is approximately two inches (the height of the overflow orifice.) ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Winterization The WPL44/WPL44NP cooler is durable enough to be left installed during the winter, though a few precautions must be taken to ensure no water freezes in the unit or lines. If the temperatures in your area drop well below freezing it may be wise to remove the water supply line from the outside faucet. Draining WPL44: 1. Turn off the water supply to the cooler. 2. Turn off and unplug cooler. 3. Remove four screws securing the back media guard and access the interior of the unit. 4. Sop up any remaining water and ensure all water is drained from both the water pump and the purge pump. 5. Disconnect and drain the water hoses and water distributor. 6. Replace the media guard. WPL44NP: 1. Turn the water supply to the cooler off. 2. Turn off and unplug cooler. Remove 4 screws securing the back media guard and access interior of unit. 3. Sop up any remaining water and ensure all water is drained from both the water pump and the purge pump. 4. Disconnect and drain the water hoses and water distributor. Covering 1. Cover the external portion of the cooler with a heavy bag and secure with straps of heavy tape. Or purchase a fitted MasterCool® Mirage exterior cooler cover, available on line at www.championcooler.com or at retail outlets. 2. An optional interior grille cover to keep air from entering the home through the window is available at ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Cooler Diagram and Parts List Item Description Part Number Available for Purchase 1 Cooler Back/Media Guard 72243 2 Back Media Pad; 2" X 24" X 35.5" CelDek 72244 3 Side Media Pad; 2" X 5.88" X 35.5" CelDek (2 ea.) 72246 4 Water distributor tray 72249 5 Tray cap 72250 6 Media Peg Clip; window cooler; PP (4 ea.) 72246 7 Media Peg; window cooler; PP (4 ea.) 72247 8a Pump assy. – Main water system ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 Trouble Shooting Chart PROBLEM PROBABLE CAUSE SOLUTION Unit will not start a. No Power a. Verify unit plugged in; and outlet is functional b. Tripped Circuit Breaker b. Reset Circuit Breaker c. Blown Fuse c. Replace fuse d. Electrical fault d. Call Champion Help line Insufficient Cooling a. Inadequate water distribution a. Check water distribution tray and (pads not saturated) hose for blockages. ‐ Verify pump operating correctly ‐ Check water supply for correct flow b. Pads dirty or covered with b. Wash dirt & deposits off pads mineral deposits or replace pads Water in air stream a. Water system has leaks or a. Check all water connections, tubing, loose connections distribution tray for loose fittings, leakage or tears. b. Water is not being absorbed b. Check condition of pads. Clean or by media pads, and entering ...
WPL44/ WPL44NP MasterCool® Mirage Window Evaporative Cooler 1B72291 MASTERCOOL PLASTIC WINDOW COOLER WARRANTY POLICY EFFECTIVE DECEMBER 1, 2011: SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS. This product is warranted against defects in workmanship and materials as listed below: One year from the date of sale, except: Two years from the date of sale on motor and pump(s). Five (5) years on Media Pads. This warranty applies only to the original purchaser of the product when it is purchased from a reputable retailer/dealer. This warranty does not apply to damage from accident, misuse, alterations, unauthorized repairs, unauthorized use, mishandling, unreasonable use, abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage, nor to the equipment or products being improperly installed or wired or maintained in violation of this Owner’s Manual. Alterations include the substitution of name brand components including, but not limited to media pads. This warranty does not cover damage caused by weather‐related elements such as wind, rain, lightening or floods, nor environmental conditions such as salt air, nor damage caused by voltage spikes or other power fluctuations. No responsibility will be accepted for damage caused by vermin, pests, pets or farm animals. We accept no liability for loss of contents, carpets, walls, foundations, ceilings or any consequential damage incurred directly or indirectly from improper installation or operation. THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE. INCLUDING WITHOUT LIMITATION, MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Within the limitations of this warranty, purchaser with inoperative units should contact customer service at 800‐643‐8341 for paperwork and instructions on the return of the unit for repair. A copy of the sales receipt is required before authorization to return a unit for repair is approved. The manufacturer will repair or replace the product, at its discretion, with return freight paid by the manufacturer. It is agreed that such repair or replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES. This warranty will be null & void if purchaser attempts to repair or replace any parts which are mechanical ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Enfriador Evaporativo de Ventana del MasterCool® Mirage Instrucciones de uso e instalación Felicitaciones por haber comprado el enfriador evaporativo plástico MasterCool® WPL44/WPL44NP. Esta unidad se fabricó con el propósito de brindarle un enfriamiento confiable y eficiente durante años. NOTA: LEA ESTAS INSTRUCCIONES ANTES DE INSTALAR EL ENFRIADOR. Siga atentamente las instrucciones de instalación de este manual. En caso contrario, podrían ocasionarse problemas relacionados con la seguridad y invalidar la garantía. Instrucciones de seguridad 1. Use la unidad únicamente con un tomacorriente monofásico con conexión a tierra de 110 V y 60 Hz. Asegúrese de que el enfriador esté APAGADO y DESENCHUFADO antes de realizar la instalación, el mantenimiento o la limpieza de la unidad. No opere la unidad con un cable o enchufe dañado ni con otras piezas dañadas o faltantes. No haga funcionar el cable debajo de la alfombra. No cubra el cable con alfombras, alfombrillas o revestimientos similares. No cable de ruta debajo de los muebles o electrodomésticos.
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Nota acerca de los enfriadores evaporativo : Ventilación: Para el Mirage® enfriador para trabajar mejor, A diferencia de los acondicionadores de aire, tiene que haber una ventana o puerta los enfriadores evaporativo necesitan un sistema de abierta en cada habitación donde el ventilación abierto y no cerrado. enfriamiento es deseado. Se requieren tanto una fuente de aire fresco como una apertura de escape para generar una correcta circulación de aire. Típicamente, una ventana parcialmente abierta o la puerta en cada cuarto(espacio) donde de enfriamiento es ESCAPE ESCAPE deseada crearán la corriente de aire correcto para la ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 PROCEDIMIENTOS DE INSTALACIÓN ADVERTENCIA: No conecte la unidad hasta haber completado la instalación. NOTA: El enfriador de ventana MasterCool WPL44 se puede instalar en una ventana a guillotina o corrediza. Espacio libre requerido: Ancho: 22"; Altura: 22". Es necesario un espacio libre de 4" por encima de la caja exterior para mantenimiento. NOTA: Asegúrese de que la ubicación elegida para la instalación sea lo suficientemente resistente como para soportar el peso de la unidad y las piezas de montaje. El peso operativo del enfriador es de 93 libras. NOTA: Se requieren al menos dos personas para instalar este enfriador de ventana. Piezas incluidas: Unidad de enfriamiento Soportes de montaje de antepecho de ventana (2) Juego de piezas de separadores de acordeón (2) Herramientas y materiales requeridos: Taladro (con cable o inalámbrico) Brocas surtidas (para realizar agujeros guía para las piezas de montaje) Llave ajustable Destornillador Phillips Silicona o masilla para todo tipo de clima para sellar el panel de relleno a la estructura de la ventana Tubería de cobre o plástico de ¼" de longitud Válvula de grifo de manguera Nivel de burbuja Instalación del enfriador Retire la unidad de la caja. Verifique que incluya todas las piezas. 1. Retire todo el material de embalaje. EN CASO DE PREGUNTAS O SI ENCUENTRA QUE HAY PARTES FALTANTES, ...
Página 18
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Instalación del enfriador (cont.) 3. Extraiga la pantalla y asegúrese de que la ventana esté abierta en toda su altura. Desde el exterior de la ventana, deslice la parte del módulo del ventilador en la ventana. Asegúrese de que la persona que esté en el interior ajuste la colocación exacta de la unidad para mantener el aspecto y las longitudes correctas de los dos separadores de acordeón (incluidos). Nota: Después de identificar la posición de la instalación, coloque un nivel de burbuja en la parte superior de la unidad y realice los ajustes necesarios para asegurarse de que la unidad esté nivelada cuando se haya completado la instalación. Se recomienda verificar que la unidad esté nivelada en distintos puntos durante la instalación. SCREW TORNILLO VENTANA WINDOW TORNILLOS SCREWS SCREWS TORNILLOS SOPORTE DE MONTAJE DE WINDOW SILL MOUNTING BRACKET ANTEPECHO DE VENTANA ANTEPECHO DE VENTANA...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Conexión de agua NOTA: Se necesitará un grifo de manguera estándar con VÁLVULA DE APAGADO SHUT OFF VALVE válvula de agua acoplada (disponible a nivel local) para conectar el suministro de agua al enfriador. TUBERÍA AL PLASTIC OR ENFRIADOR DE COPPER LINE 1. Se requiere un suministro de agua constante para el PLÁSTICO O COBRE TO COOLER funcionamiento del enfriador. Si se obtiene agua de un grifo externo, instale un grifo de manguera y una válvula de cierre. 2. Instale una tubería plástica o de cobre hasta el grifo de manguera y conéctela a la válvula de flotador. GRIFO DE SILL COCK CONEXIÓN DE MANGUERA STD.
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Sistema eléctrico El sistema eléctrico no requiere mantenimiento general. El siguiente diagrama de cableado es sólo a modo de referencia. (SÓLO EN WPL44, O (WPL44 ONLY, OR INSTALADA POR EL DUEÑO) OWNER-INSTALLED) BOMBA BOMBA DE MOTOR DEL PRINCIPAL PURGA CONTROL VENTILADOR TIERRA (AMA/VER) COMÚN (BLANCO) CABLE DE ALIMENTACIÓN ALTA (NEGRO) BAJA (ROJO) MEDIA (AZUL) ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 INSTRUCCIONES DE USO El Mirrage posee un panel de control electrónico FAN (Ventilador) táctil en la esquina superior derecha. Velocidades Fan Speeds: Antes de encender la unidad, asegúrese de del ventilador: que está conectada, que el suministro de agua a la bomba está encendido y que se HI MED LO (Baja) cuenta con una correcta ventilación, tal (Alta) (Media) Encendido Power como se indica en la página 16 de este manual. ON/OFF Bomba de agua Water Pump (Encendido/Apagado) Encendida/ On/Off Apagada Nota: Estas unidades se pueden controlar PUMP PUMP por medio de 3 botones ubicados en el ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Servicio Usuario Instrucciones El mantenimiento en enfriadores evaporativo es mínimo, pero sí muy importante para un funcionamiento y eficacia adecuados. La inspección periódica del interior del enfriador reducirá la posibilidad de un enfriamiento deficiente debido a una distribución de agua insuficiente o irregular. NOTA: Para tareas de mantenimiento general, la unidad puede drenarse rápidamente al retirar la grifería de rebose del fondo. Éste no es el drenaje apropiado para el acondicionamiento para el invierno (ver procedimientos en la sección Acondicionamiento para el invierno). Mantenimiento anual (puede ser necesaria una mayor frecuencia en áreas con aguas duras) Limpieza PRECAUCIÓN: Desconecte la alimentación eléctrica y apague la unidad durante todas las tareas de mantenimiento. Cierre el suministro de agua antes de retirar el fondo por limpieza o mantenimiento. 1. Retire la protección del medio posterior (como se indica abajo). 2. Inspeccione las almohadillas en su sitio. Retire las almohadillas del medio de la protección posterior desatornillando los ganchos de sujeción. Tenga cuidado de no dañar el medio mientras los retira. Examine visualmente ambas caras de las almohadillas del medio. Observe si hay alguna obstrucción, acumulación mineral o crecimiento de moho, rotura o alguna otra anomalía. 3. DESCONECTE LA MANGUERA DE SUMINISTRO DE AGUA 4. SEPARE LA SECCIÓN DE LA UNIDAD 1. RETIRE LOS 4 TORNILLOS DE LA SECCIÓN DE ESPALDA...
Página 23
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Lave las almohadillas con una manguera de jardín. No utilice una lavadora a presión. Controle el distribuidor de agua por si existe obstrucción o excesiva acumulación de polvo. Coloque el medio en un lugar seguro hasta que termine con todo el mantenimiento. Lave el depósito de manera exhaustiva con un cepillo de cerdas suaves. Utilice abundante solución de agua y vinagre blanco, si es necesario, para remover el crecimiento de algas. Limpie las áreas alrededor de la bomba, el filtro y el flotador para asegurarse de que no quedan restos de algas. ADVERTENCIA: No utilice químicos abrasivos para limpiar las partes interiores del enfriador. No utilice limpiadores abrasivos en el exterior del cuerpo del enfriador para conservar su resistencia a los rayos UV. 7. Enjuague minuciosamente después de haber utilizado cualquier solución de limpieza en el interior o el exterior de la unidad. Bomba del sistema de agua: 1. La bomba de agua es una unidad independiente que no requiere más mantenimiento que evitar que los residuos o la corrosión interfieran en el libre movimiento de las piezas. 2. Cerciórese de que la conexión de la manguera a la bomba esté en buenas condiciones. Flotador de agua: 1. El nivel del flotador está ajustado de fábrica para un rendimiento óptimo; sin embargo, se pueden realizar leves ajustes doblando el brazo del flotador para un nivel de agua diferente. 2. El nivel de agua máximo recomendado es aproximadamente de dos pulgadas (la altura del orificio de desborde). Distribuidor de agua 1. Revise la sección de distribución de agua para asegurarse de que todos los orificios están sin obstrucciones. 2. Verifique que las conexiones de la manguera estén en buen estado y no haya ningún pliegue o rotura. ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Acondicionamiento para el invierno El enfriador WPL44/WPL44NP es lo suficientemente duradero como para dejarlo instalado durante el invierno, aunque hay que tomar algunas precauciones para garantizar que el agua no se congele en la unidad o las tuberías. Si en su área las temperaturas descienden a varios grados bajo cero, es conveniente retirar la tubería de suministro de agua del grifo exterior. Drenaje WPL44: 1. Cierre el suministro de agua al enfriador. 2. Apague y desconecte el enfriador. 3. Retire los cuatro tornillos que fijan la protección posterior del medio y el acceso al interior de la unidad. 4. Absorba todo resto de agua y asegúrese de drenar toda el agua tanto de la bomba de agua como de la bomba de purga. 5. Desconecte y drene las mangueras de agua y el distribuidor de agua. 6. Vuelva a colocar la protección del medio. WPL44NP: 1. Cierre el suministro de agua al enfriador. 2. Apague y desconecte el enfriador. Retire los 4 tornillos que fijan la protección posterior del medio y el acceso al interior de la unidad. 3. Absorba todo resto de agua y asegúrese de drenar toda el agua tanto de la bomba de agua como de la bomba de purga. 4. Desconecte y drene las mangueras de agua y el distribuidor de agua. Cubrimiento 1. Cubra la parte externa del enfriador con una bolsa resistente y fíjela con tiras de una cinta gruesa. NOTA: Se encuentra disponible una cubierta para el enfriador ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 Tabla de solución de problemas PROBLEMA CAUSA PROBABLE SOLUCIÓN No arranca la unidad a. No hay energía a. Compruebe que la unidad esté conectada y que el tomacorriente esté operativo b. Disyuntor activado b. Restablezca el disyuntor c. Fusible quemado c. Reemplace el fusible d. Falla eléctrica d. Llame a la línea telefónica de ayuda de Champion Enfriamiento deficiente a. Distribución de agua inadecuada a. Revise la bandeja de distribución de (almohadillas no saturadas) agua y la manguera por si existen obstrucciones. ‐ Compruebe que la bomba funciona ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 PÓLIZA DE GARANTÍA DEL ENFRIADOR DE VENTANA PLÁSTICO MASTERCOOL VÁLIDA AL 1 DE DICIEMBRE DE 2011: PARA CUALQUIER RECLAMO RELACIONADO CON LA GARANTÍA ES NECESARIO PRESENTAR EL RECIBO COMO PRUEBA DE COMPRA. Este producto posee garantía por defectos en la fabricación y en los materiales según se detalla a continuación: Un año desde la fecha de venta, excepto: Dos años desde la fecha de venta para el motor y bomba(s). Cinco (5) años para las almohadillas del medio. Esta garantía es aplicable solamente al comprador original del producto siempre que haya adquirido el producto en una tienda o un distribuidor de buena reputación. Esta garantía no es aplicable a productos que se hayan dañado como consecuencia de accidentes, uso indebido, alteraciones, reparaciones no autorizadas, uso no autorizado, manipulación incorrecta, uso no razonable, abuso, incluida la falta de mantenimiento razonable, el desgaste normal o cuando la tensión de conexión supera en más de 5% aquélla especificada en la placa del fabricante. Asimismo, esta garantía tampoco es aplicable al equipo o a los productos que fueran instalados, conectados o sometidos a mantenimiento de forma incorrecta sin seguir las especificaciones de este Manual del Usuario. Las alteraciones incluyen la sustitución de componentes de marca, incluidas, entre otros, las almohadillas del medio. Esta garantía no cubre daños causados por elementos relacionados a factores climáticos como viento, lluvia, rayos o inundaciones, así como tampoco aquellos relacionados a condiciones ambientales como aire salobre o daños causados por picos de tensión u otras fluctuaciones de energía. No se aceptará ninguna responsabilidad por daños ocasionados por alimañas, plagas, mascotas o animales de granja. No asumimos responsabilidad alguna por ningún daño o pérdida de contenidos, alfombras, paredes, cimientos o cielorrasos producidos como consecuencia directa o indirecta de una instalación o funcionamiento inadecuados. ESTE PRODUCTO NO FUE DISEÑADO PARA USO COMERCIAL. LA PRESENTE ES LA ÚNICA GARANTÍA QUE OFRECE EL FABRICANTE CON RESPECTO A LOS PRODUCTOS Y, HASTA EL GRADO MÁXIMO PERMITIDO POR LA LEY, REEMPLAZA A CUALQUIER OTRA GARANTÍA, POR ESCRITO O TÁCITA, QUE OPERE DE PLENO DERECHO O DE OTRA FORMA. SE INCLUYE, SIN LIMITACIONES, LA COMERCIABILIDAD Y/O APTITUD PARA UN PROPÓSITO EN PARTICULAR. Ningún empleado, agente, distribuidor u otra persona se encuentra autorizado a brindar garantías o condiciones en nombre del fabricante. El cliente será responsable por todos los costos relacionados con el retiro o la reinstalación y el envío del producto para su reparación. Dentro de las limitaciones de esta garantía, el comprador que posea unidades que no funcionen correctamente debe contactarse con el servicio de atención al cliente al 800‐643‐8341 para recibir los documentos y las instrucciones a fin de realizar la devolución de la unidad para su reparación. Es necesario presentar una copia del recibo de compra para que se apruebe la autorización de devolución de la unidad para su reparación. El fabricante reparará o reemplazará el producto, según lo crea conveniente, y se hará cargo de los gastos de envío de la devolución al cliente. Se acuerda que la reparación o el reemplazo son las únicas soluciones que el fabricante tiene ...
WPL44/ WPL44NP MasterCool® Mirage Enfriador Evaporativo de Ventana 1B72291 IMPORTANT INFORMATION / MAINTNENANCE LOG INFORMACIÓN IMPORTANTE / MANTENIMIENTO DE LOS REGISTROS We recommend keeping a maintenance log for each year. The following table is a suggested format supplied for your convenience. Se recomienda mantener un registro de mantenimiento para cada año. La siguiente tabla es una propuesta de formato suministrado por su convnenience. Model Number / Número de modelo ________________________________________ Date of Purchase / Fecha de compra _______________________________________ Location of Purchase/ localización de la compra _____________________________...