MastrerCool WPL44NP Instrucciones De Funcionamiento Y Instalacion página 10

Enfriador evaporativo de ventana
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WPL44/ WPL44NP   MasterCool® Mirage Window Evaporative Cooler 
 
 
 
 
CAUTION: Do not use harsh chemicals to clean the interior portions of the cooler. Do not use abrasive cleaners 
on the exterior of the cooler body to maintain its UV resistance. 
7. Rinse thoroughly after using any cleaning solutions have been used on the interior or exterior of the unit. 
Water System Pump: 
1. The water pump is a self‐contained unit that should require no maintenance other than ensuring that no 
debris or corrosion interferes with free movement of the parts. 
2. Ensure hose connection to pump is in good condition.  
Water Float: 
1. The float level is factory set for optimum performance, however moderate adjustments can be made by 
bending the float arm for a different water level. 
2. The maximum recommended water level is approximately two inches (the height of the overflow orifice.) 
Water Distributor  
1. Inspect the water distribution section to ensure all orifices are clear.   
2. Verify the hose connections are in good order and no kinks or tears are present.  
Water Drain Overflow (WPL44NP) 
1. Unscrew the drain overflow pipe and check the condition of the gasket at the bottom of the fixture. When 
reinstalling, ensure the standpipe fixture is secure and there is no leakage after the reservoir is filled. 
NOTE:  If during usage of the cooler you start noticing low saturation of pads and insufficient cooling, or 
leakage from the cooler, check the O‐ring at the base of the standpipe. This is the most likely cause of leakage 
on this unit. 
Water Purge Pump (WPL44 only) 
1. The purge pump installed on the WPL44 model is timed to release 10‐12 gallons of water every 6 hours.  
2. Check that the purge pump and strainer are corrosion‐free with freely moving parts. 
 
 
 
3. Wash pads with a garden hose. Do not  
     use a pressure washer. 
4. Check water distributor for blockage  
     or excessive buildup of dust. 
5. Set media in a safe place until all 
     maintenance is complete. 
6. Wash out reservoir thoroughly using a 
     soft bristle brush. Use plenty of water  
     and a white vinegar solution, if 
     necessary, to remove algae growth.  
     Clean areas around pump, strainer  
      and float to ensure no algae  
      growth remains.  
 
 
 
10 