that the adapter is properly inserted into the power outlet. Observe the display or lights that
indicate charging status.
NOTE: When starting to charge a fully discharged battery, the charging process may start and
stop during the first few minutes.
Always keep liquids away from batteries. If batteries become wet, discontinue use immediately
and dispose of battery properly.
To extend the run-time of your battery, avoid running in temperatures less than 41˚F (5˚C) or
higher than 95˚F (35˚C) for extended periods of time.
Store battery in a cool, dry place. Store with a charge of 40-50%.
If using multiple batteries, make sure that each battery is labeled (1, 2, 3 or A, B, C, etc.)
and rotate on a regular basis. Batteries should not be left dormant for more than
90 days at a time.
Battery Charge Indicator Gauge
When the single or double battery is not
attached to the OxyGo NEXT Concentrator, you
can check the battery gauge on the battery to
determine the amount of charge available.
Determine the amount of battery charge
available by pressing the green battery icon
button and observing how many LEDs
illuminate.
4 LEDs Light: 75% to 100% full
3 LEDs Light: 50% to 75% full
2 LEDs Light: 25% to 50% full
1 LED Lights: 10% to 25% full
1 LED Blinks: Battery is less than 10% full
and needs to be recharged
Power Supply Overview
The OxyGo NEXT AC power supply (1400-3040) is used to power the OxyGo NEXT
concentrator from an AC power source.
The OxyGo NEXT AC power supply is specifically designed for use with the OxyGo NEXT Oxygen
Concentrator (IO-500). The AC power supply provides the precise current and voltage
required to safely power the OxyGo NEXT and is designed to operate from specified AC power
sources. When used with AC power sources, the power supply automatically adapts to input
voltages from 100V to 240V (50-60HZ) permitting use with most power sources
throughout the world.
The AC power supply will charge the OxyGo NEXT Batteries when used with AC input power.
Due to aircraft power limitations, the AC Power Supply cannot be used to charge the OxyGo
NEXT Battery when used on an aircraft.
The AC power supply is used with the following components:
1.
Power supply with attached power output cable to connect to the OxyGo NEXT.
2.
AC power input cable to the power source.
The DC power cable (1400-1050) is designed for use with the OxyGo NEXT Oxygen
Concentrator (IO-500). The DC power input cable connects directly to the automobile
cigarette lighter or auxiliary DC power supply.