AVS Electronics OUTSPIDER PA Manual De Instrucciones página 44

Ocultar thumbs Ver también para OUTSPIDER PA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Hole for joint adjustment
In case you need to adjust the position of
the sensor, the board is designed with a
hole to easily access the joint screw,
without having to remove the board from
its housing.
The hole is placed over the top PIR so in
order to use it, it is necessary to lift the
adhesive foam located over the hole.
E
HOLE FOR JOINT
ADJUSTMENT
N
G
Recommendations OUTSPIDER PA
OUTSPIDER PA is equipped with a buzzer
and a series of LED in order to give an
optical-acoustic signal (Walk Test) even if
a block is applied to the sensor.
1.0
1.5
2.2
2.7
MW
GIALLO
YELLOW
ROSSO
RED
USB
LED
BUZZER
LED
Yellow Steady:
Passive infrared alarm
signal
Fast flashing:
Antimask alarm signal
Slow flashing:
Dirty lenses fault signal
Flashing:
A lte rna te ly wi th re d
L E D f o r a b o u t 6 0
seconds at first feeding
Red
Steady:
General alarm signal
Flashing:
Alternately with yellow
L E D f o r a b o u t 6 0
seconds at first feeding
When powering the first time, OUTSPIDER
PA remain inhibited for about 60 seconds,
during which the yellow and red LED, if
enabled, flash alternatively and the buzzer
emits an intermittent signal.
Recommendations OUTSPIDER DT
OUTSPIDER DT is equipped with a buzzer
and an LED in order to give an optical-
acoustic signal (Walk Test) only if a block
is not applied to the sensor or it is set in
Security mode.
MW
RED
GREEN
YELLOW
GIALLO
ROSSO
VERDE
BUZZER
LED
LED
Yellow Steady:
Passive infrared alarm
signal
Fast flashing:
Antimask alarm signal
Slow flashing:
Dirty lenses fault signal
Flashing:
A lte rna te ly wi th re d
L E D f o r a b o u t 6 0
seconds at first feeding
Red
Steady:
General alarm signal
Flashing:
Alternately with yellow
L E D f o r a b o u t 6 0
seconds at first feeding
Green Steady:
Mi c ro wa ve s e c t i o n
alarm signal
When powering the first time, OUTSPIDER
DT remain inhibited for about 60 seconds,
during which the yellow and red LED, if
enabled, flash alternatively and the buzzer
emits an intermittent signal.
- 44 -
Recommendations OUTSPIDER PA and
OUTSPIDER DT WS (UB) (U)
OUT SPIDER PA WS(UB) (U) and
OUTSPIDER DT WS(UB) (U) are equipped
with a buzzer and a led to provide a visual-
acoustic warning (Walk Test)
1.0
1.5
2.2
2.7
MW
RED
ROSSO
USB
BUZZER
LED
LED
Red
Steady:
General alarm signal
Flashing:
Alternately with yellow
L E D f o r a b o u t 6 0
seconds at first feeding
At the f irst power supply of the
OUT SPIDER PA WS (UB) (U) and
OUTSPIDER DT WS (UB) (U) it is
necessary to let the sensor rest with the
cover on for about 90 seconds during
which time it acquires the average signal
of the various analog signals it will be
controlling. It is important that the cover
is kept closed so that it does not distort
the average anti-mask signal and to avoid
false detections.
1.5
2.2
2.7
BATT
USB

Publicidad

Tabla de contenido
loading

Tabla de contenido