DPA−...−CRVZS
Remove condensate
Drain the condensate from the air reservoir.
S
With DPA− −CRVZS2:
1. Switch off the pressure booster combination.
2. Remove the tubing from connection P2.
3. Insert a quick coupling plug KS4 in the quick coupling socket at P2.
4. Place the pressure booster combination at an angle.
With DPA− −CRVZS5(10)(20):
1. Switch off the pressure booster combination.
2. Open the condensate drain (SW 8).
9
Dismantling
With DPA− −CRVZS10(20):
1. Close the 3−way start−up valve on the output side P2.
2. Close the 3−way start−up valve on the input side P1.
3. Close the 3−way start−up valve between the pressure booster DPA and the
air reservoir CRVZS (è Fig. 5).
4. Turn the regulator button in an anti−clockwise direction as far as possible.
5. Switch the complete system into a pressureless state.
When doing this note the display on the pressure gauges.
6. Loosen the pneumatic connections.
Festo DPA−...−CRVZS 0806NH English