Panasonic CS-E10KB4EA Guía Rápida página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TROUBLESHOOTING
The following symptoms do not indicate malfunction.
The following symptoms do not indicate malfunction.
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic fan speed
setting.
Airfl ow continues even after operation has stopped.
Operation is delayed a few minutes after restart.
Outdoor unit emits water/steam.
Timer indicator is always on.
Power indicator blinks during HEAT mode with no warm air
supply (and louver is closed).
Indoor fan stops occasionally during heating operation.
Power indicator blinks before the unit is switched on.
Cracking sound during operation.
Check the following before calling for servicing.
Check the following before calling for servicing.
Heating/Cooling operation is not working effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the remote
control.
Patrol sensor or e-ion indicator on the indoor unit is
blinking.
8
SYMPTOM
SYMPTOM
SYMPTOM
SYMPTOM
► • Condensation effect due to cooling process.
► • Refrigerant fl ow inside the unit.
► • This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
► • This helps to remove the surrounding odours.
► • Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
► • The delay is a protection to the unit's compressor.
► • Condensation or evaporation occurs on pipes.
► • The timer setting repeats daily once set.
► • The unit is in defrost mode (and AIR SWING is set to
AUTO).
► • To avoid unintended cooling effect.
► • This is a preliminary step in preparation for the operation
when the ON timer has been set.
► • Changes of temperature cause the expansion/
contraction of the unit.
► • Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
► • Check if the unit has been installed at an incline.
• Close the front panel properly.
► • Insert the batteries correctly.
• Replace weak batteries.
► • Check if the circuit breaker is tripped.
• Check if timers have been set.
► • Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
► • Stop Patrol or e-ion operation then restart. If the patrol
sensor or e-ion indicator still blinking, please consult
authorized dealer.
CAUSE
CAUSE
CHECK
CHECK

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cu-e10hbeaCu-2e15lbeCu-2e18lbeCu-3e18lbeCu-4e23lbeCu-4e27cbpg ... Mostrar todo

Tabla de contenido