– The outside of the unit should be
cleaned thoroughly and any harmful
substances removed. Alternatively, a
sealed coating may be applied before
the unit is removed from the danger ar-
ea. All unit parts are to be considered
contaminated when they are removed
from the danger area. To avoid distribu-
tion of the dust, you must take the ap-
propriate measures.
– In the framework of maintenance and
repair work all contaminated objects
that cannot be cleaned satisfactorily
must be disposed of. Such objects must
be disposed of in impermeable bags in
accordance with the valid provisions for
the disposal of such waste.
– When transporting or maintaining the
device, the suction opening must be
closed with the plug.
WARNING
Safety equipment for preventing hazards
must be serviced and maintained regularly.
This means that the manufacturer's staff or
persons trained by the manufacturer must
check the equipment for proper functioning
at least once a year, i.e. check for leaks, fil-
ter damage, functioning of the controlling
elements, etc.
ATTENTION
Risk of damage! Do not use detergents
containing silicone to clean.
– No outside help is required for carrying
out basic maintenance and cleaning.
– The appliance surface and the inside of
the container should be cleaned regu-
larly using a damp cloth.
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or higher
breath-safe masks while carrying out main-
tenance tasks (such as changing filters).
Exchanging the flat pleated filter
Open filter door.
Take out the flat folded filter.
Dispose off the used flat-folded filter in
a dust-tight bag according to the statu-
tory provisions.
Remove the dirt that has accumulated
on the pure air side.
Insert new flat-folded filter.
Close the filter door, it must lock into
place.
Replacing the fleece filter bag/dust
Close the suction connection
Illustration
Close the suction connection, see wet
vacuuming.
Exchange the fleece filter bag
Illustration
Release and remove the suction head.
Pull the fleece filter bag (special acces-
sories) towards the rear.
Fold in the lock latch and tightly close
the fleece filter bag (special accesso-
ries).
Dispose of the used fleece filter bag
(special accessories) in a dust-tight bag
according to statutory provisions.
Attach a new the fleece filter bag (spe-
cial accessories).
Insert and lock the suction head.
Replace the disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Attach the new disposal bag.
Pull disposal bag over the container.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
– 6
EN
bag