General
A range of ambient temperature compensated overload relays
complying with VDE 0660; IEC 292-1 and BS 4941 standards.
The relays are designed to provide protection of both single and three
phase
motors against current overloads and loss of phase supply.
Calibrated in full load current.
Full load current
Min
Mid
Max
Min
0.21
0.26
0.32
0.25
0.32
0.40
0.48
0.38
0.48
0.60
0.72
0.56
0.72
0.94
1.10
0.84
1.10
1.35
1.60
1.30
1.60
2.00
2.40
1.90
2.40
2.95
3.50
2.80
3.50
4.45
5.40
4.10
5.40
6.70
8.0
6.30
8.00
10.0
12.0
9.40
12.0
15.0
18.0
14.0
18.0
22.0
26.0
21.0
26.0
31.0
*Note:
Due to the overlapping contactor current range, either fuse
size may be used depending upon the current rating of the
contactor used.
Fitting overload relay to contactors
The overload relay is supplied with a mounting/coupling bracket for
fitting into the 10hp direct on-line starter, 25A (AC1) 'ACCESS'
contactor and size 1 'MAX 0' control relays and contactors.
alternative bracket supplied should be used when connecting the
overload relay to the size 2-4 pole 'MAX 0' series of contactors (see
figure 2).
When connecting the overload relay, ensure that the terminal screws of
the contactor are loosened and that the connecting blades are fully
inserted into the contactor terminals. The coupling bracket should be
positioned in the appropriate mounting slot/hole in the contactors
moulding (see figure 3).
General
Fitted to the overload, this unit provides a wire in/wire out facility for
remotely mounted overloads relay on a flat surface.
Fitting adaptor to overload relay
When connecting the adaptor to the overload relay, ensure that the
termination screws on the adaptor are loosened and that the
connecting blades on the overload relay are fully inserted into the
adaptor terminals The mounting coupling bracket should be re-fitted as
in Figure 4.
2
RS Stock No.
Full Load Current
0.21 - 0.32A
0.32 - 0.48A
0.48 - 0.72A
0.72 - 1.10A
1.10 - 1.60A
1.60 - 2.40A
2.40 - 3.50A
3.50 - 5.40A
5.40 - 8.0A
8.0 - 12.0A
12.0 - 18.0A
18.0 - 26.0A
21.0 - 31.0A
Trip current
Short circuit
fuse protection
Mid
Max
Max. BS88 fuse size
0.31
0.38
2A
0.47
0.56
2A
0.70
0.84
2A
1.10
1.30
4A
1.60
1.90
6A
2.30
2.80
6A
3.40
4.10
10/16A*
5.20
6.30
16A
7.80
9.40
20A
12.0
14.0
25/32A*
17.0
21.0
32A
63A
80A
Technical specification
Contact thermal rating (lth)
Maximum voltage
Main terminal capacity ____________________________2 x 4mm
Trip/alarm terminal capacity ______________________2 x 2.5mm
Ambient temperature
compensation range __________________________-5°C to +60°C
Minimum storage temperature
Weight
__________________________________________0.12kg
Breaking capacity
Trip/alarm contacts VA
Breaking capacity
Trip/alarm contacts W
RS Components shall not be liable for any liability or loss of any nature (howsoever
caused and whether or not due to RS Components' negligence) which may result
from the use of any information provided in RS technical literature.
Allgemein
Eine Reihe von Umgebungstemperatur-kompensierten Überlastrelais.
Die Relais sind konstruiert, um Schutz für sowohl Einzelphasen- als
auch Dreiphasen-Wechselstrommotoren vor Stromüberlasten und
Verlust von Phasennetz zu bieten.
Kalibriert im Vollaststrom.
Strombereiche
Vollaststrom
Min.
Mitt.
Max.
The
0,21
0,26
0,32
0,32
0,40
0,48
0,48
0,60
0,72
0,72
0,94
1,10
1,10
1,35
1,60
1,60
2,00
2,40
2,40
2,95
3,50
3,50
4,45
5,40
5,40
6,70
8,0
8,00
10,0
12,0
12,0
15,0
18,0
* Hinweis:
Aufgrund des überlappenden Schützstrombereichs
können beide Sicherungsgrößen benutzt werden,
abhängig vom Stromnennwert des verwendeten
Schützes.
____________________________10A
______________________________660V
________________________-35°C
V
120,
240,
380,
500,
600,
520,
V
12,
24,
55,
35,
22,
18,
Vollaststrom
343-896
0,21 - 0,32A
343-903
0,32 - 0,48A
343-919
0,48 - 0,72A
344-956
0,72 - 1,10A
344-962
1,10 - 1,60A
344-978
1,60 - 2,40A
344-984
2,40 - 3,50A
344-990
3,50 - 5,40A
343-004
5,40 - 8,0A
343-010
343-026
12,0 - 18,0A
Auslösestrom
Kurzschluß-Sicherungsschutz
Min.
Mitt.
Max.
Max. Sicherungsgröße
0,25
0,31
0,38
0,38
0,47
0,56
0,56
0,70
0,84
0,84
1,10
1,30
1,30
1,60
1,90
1,90
2,30
2,80
2,80
3,40
4,10
4,10
5,20
6,30
6,30
7,80
9,40
9,40
12,0
14,0
14,0
17,0
21,0
2
2
440,
500
480,
430
115,
240
12,
10
RS Best-Nr.
8,0 - 12,0A
2A
2A
2A
4A
6A
6A
10/16A*
16A
20A
25/32A*
32A