MAINTENANCE AND CLEANING
Maintenance
Clean the body of the appliance, air inlet and outlet with dry soft cloth frequently.
Do not use water, bleach, Never immerse the appliance in water or any other liquid.
Never use aggressive or flammable cleaning agents such as bleach or alcohol to clean any part of
the appliance.

Cleaning Pre-Filter

Clean the Pre- Filter every 3 months for optimal functioning. Clean it more frequently if appliance is
used in a dusty environment.
Note: Only the pre-filter is washable. All other filters are NOT washable.
1. Always unplug the appliance before you clean it. Remove the pre-filter.
2. Rinse the pre-filter under a running faucet. If the pre-filter is very dirty, use vacuum or a soft
brush to remove dust.
3. Air-dry the pre-filter.
4. Make sure the pre-filter is completely dry before inserting back into the appliance.
5. Make sure all the hooks have been correctly attached to the appliance.
Air Quality Sensor
Clean the air quality sensor every 2 months for optimal functioning. Clean it more frequently if
appliance is used in a dusty environment.
Clean the air quality sensor inlet and outlet with a soft brush. Remove the air quality sensor cover.
Clean the air quality sensor, the dust inlet and outlet with a lightly moistened cotton swab. Dry
them with a dry cotton swab. Reattach the air quality sensor cover.