Automatic Operation, Step by Step continued...
Press the Next
Button to select the current DAY (1–15) of the Skip Days
schedule. This determines when the watering interval will begin. At the day
change (midnight), the DAY number automatically increases by one.
When the SKIP and DAY numbers are equal, watering will occur at the first
scheduled start time.
Note: If an Odd/Evn schedule is in use, it must be set to "OFF" before a
Skip Days schedule can be set. (See page 18, "What the Display Means.")
Odd/Even Days Schedule
Turn the Dial to ODD/EVEN. Press the
EVN or OFF.
Note: Odd/Evn schedule overrides the Skip Days or Daily schedules and
must be set to "OFF" to use another type of schedule.
Note: ODD days will not water on the 31st of a month or Feb. 29 during leap
year.
4.Turn the Dial to Start Times
Turn the Dial to Start Time 1. Press the
this Program to start.
Note: OFF settings are located between 11:59 a.m./12:00 p.m.,
and 11:59 p.m./12:00 a.m.
If desired, add second and third Start Times to this PROGRAM by changing
the Dial position to 2 or 3 and repeating the above procedure.
5.Turn the Dial to Valve Run Times
Turn the Dial to the number of the valve you want to operate. Press the
+/-
Buttons to set the number of minutes to water. The values larger than
one hour show as hours and tenths of hours, for example, 1.1 hour means
1 hour and 6 minutes. Repeat for each valve you want to operate within
the selected Program.
To set another PROGRAM, repeat steps 2 through 5.
Your program is now complete and ready to run.
Set the Function Switch to Run
reaches the next start time.
14
+/-
Buttons to select ODD,
.
+/-
Buttons to the time you want
.
and your system will run when the clock