SAVE THESE INSTRUCTIONS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance
with UL 1598. Before attempting installation of any recessed lighting fixture, check your local electrical building code.
This code sets the wiring standards and installation requirements for your locality and should be understood before
starting work. Use of non-Juno trims voids Juno warranty.
WARNING: Risk of fire. Do not install insulation within 3 inches of fixture sides or wiring compartment, nor above
fixture in such a manner as to entrap heat. (Fig. 1)*
* In Canada, when insulation is present, Type IC fixtures must be used.
TYPE TC FOR NON-INSULATED CEILINGS
3"
Juno Type TC fixtures are designed for installations where housing and
J-box will not come in contact with insulation. Insulation must be spaced
3" away from housing and J-box (Fig. 1). Improper fixture operation may
indicate improper insulation application.
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
with Lutron Hi-Lume
Figure 1
TC920LED & TC922LED
®
Commercial Recessed Housing
HOUSING INSTALLATION
BUTTERFLY
BRACKET
Figure 2
Step 1. Install housing into ceiling cavity by inserting 1/2" EMT , 3/4"
or 1-1/2" C-Channel, linear flat bars or Real Nail 3 bar hangers into
butterfly style mounting brackets (Fig. 2).
Step 2. Adjust butterfly mounting brackets
by loosening the carriage adjustment
bolt so bottom of plaster ring is flush with
finished ceiling line. Mounting brackets
have total vertical adjustment of 3"
(Fig. 3).
Step 3. Follow steps under Electrical
Connection.
Step 4. Cut appropriate sized hole.*
If necessary, adjust fixture for ceiling thickness by loosening hex screws
that attach round housing to the plaster ring.
* Note: Cut 5-5/8" (for 5" housings) or 6-7/8" (for 6" housings) opening.
© 2014 Juno Lighting LLC
Driver (-L Option)
Figure 3
Hex Screws
Figure 4
Rev 5/14
P3693
CARRIAGE
BOLT
pg 1 of 4

Publicidad

loading

Resumen de contenidos para JUNO TC920LED

  • Página 1 Before wiring to power supply, turn off electricity at the fuse or circuit breaker box. NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with UL 1598. Before attempting installation of any recessed lighting fixture, check your local electrical building code.
  • Página 2: Installation Instructions

    For hyperbolic trims, follow instructions provided with the trim. Figure 8 1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com © 2014 Juno Lighting LLC Rev 5/14 P3693 pg 2 of 4...
  • Página 3 ® Commercial Recessed Housing FIXTURE DIMMING Fixture Ground Lutron driver option for TC920LED, TC922LED and Chicago Plenum and Emergency Options Lutro Universal input voltage (120VAC thru 277VAC) housing consult Lutron website for specific dimmer compatibility. For use with Lutron Fluorescent 3-wire dimmers...
  • Página 4 Juno Lighting Group’s factory after prior written return authorization has been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantability.
  • Página 5 Antes de cablear a la fuente de energía, apague la electricidad en la caja de fusibles o cortacircuitos. NOTA: Los accesorios empotrados Juno están diseñados para cumplir con los últimos requisitos NEC y están enlistados en cumplimiento completo con UL 1598. Antes de intentar la instalación de cualquier accesorio luminoso empotrado, revise su código eléctrico de construcción local.
  • Página 6 INSTRUCCIONES DE INSTALACIÓN Carcasas Empotradas Comerciales TC920LED y TC922LED con Impulsador Hi-Lume de Lutron (Opción -L) ® INSTRUCCIONES DE CONEXIÓN ELÉCTRICA Paso 3. Pele el alambre de suministro 3/8” Paso 1. Proporcione el servicio eléctrico, según su código eléctrico local, a la caja de empalmes e inserte cada alambre de suministro en el ubicada en el marco de yeso.
  • Página 7 Hi-Lume de Lutron (Opción -L) ® REGULACIÓN DEL ACCESORIO Tierra del Opción de impulsador Lutron para TC920LED, TC922LED y Chicago Accesorio Plenum y Opciones de Emergencia Carcasa de entrada de voltaje universal (120VCA hasta 277VCA), consulte Control d el sitio web de Lutron para la compatibilidad del regulador específico.
  • Página 8: Diagrama De Conexiones Para Control Digital Ecosystem

    Juno Lighting Group proporciona una garantía limitada de cinco años sobre los componentes LED a partir de la fecha de compra. La obligación de Juno Lighting Group está expresamente limitada a la reparación o reemplazo, sin cargo, en la fábrica de Juno Lighting Group después de que la autorización de retorno por escrito se haya otorgado.

Este manual también es adecuado para:

Tc922led