plug out of the contact.
EN
Attention! The wall-plug must be properly connected to a separate
electrical circle that is provided with a protector. It must be earthed.
Water heaters fitted with a supply cord without a plug.
The appliance has to be connected to a separate electricity circuit of the
stationary electrical wiring.The connecting has to be constant- with no plug
contacts. The circuit has to be supplied with a safety fuse (16A) and with
inbuilt device to ensure disconnection of all pole pieces in the conditions of
over-voltage from category III.
The connecting of the conductors of the supply cord of the appliance has to
be carried out as follows:
conductor with brown insulation – to the phase conductor of the
electrical wiring (L)
conductor with blue insulation- to the neutral conductor of the wiring (N)
conductor with yellow-green insulation – to the safety conductor of the
wiring ⏚.
3.2.
Models without power cord
The appliance has to be connected to a separate electricity circuit of the
stationary electrical wiring. The circuit has to be supplied with a safety fuse
16A (20A for power > 3700W). Copper single core (rigid – non stranded)
conductor shall be used for the connection – cable 3 x 2.5mm² (cable 3 x
2.5mm² for power > 3700W).
The electrical circuit supplying the appliance must have an in-built device
ensuring the splitting of all terminal poles under conditions of super-voltage
of category III.
To install the power supply wire to the boiler, remove the plastic cover (Fig.2).
Connect the power wires in compliance with the marks on the terminals, as
follows:
the phase - to mark A, A1, L or L1;
the neutral - to N (B or B1 or N1)
The safety wire must be obligatory connected to the screw joint marked
with ⏚ .
After the installation, put the plastic cover back in its place!
Explanations to Fig. 4:
T2 - thermal switch; T1 - thermal regulator; S - switch (for models that have
one); R1, R2 - heater; IL - light indicator
F - flange; KL - luster terminal; EC - electronic control
RUST PROTECTION
VI.
1.
Magnesium anode
The magnesium anode protects the water tank's inner surface from
corrosion.
The anode element is an element undergoing wear and tear and is subject
to periodic replacement.
In view of the long-term and accident free use of your water heater, the
manufacturer recommends periodic inspections of the magnesium anode's
condition by a qualified technician and replacement whenever required,
and this could be performed during the appliance's technical preventive
maintenance.
The magnesium anode undergoes wear and when the wear is more than
50% (fifty percent) the magnesium anode shall be replaced with a new one,
provided by the manufacturer.
For replacements, please contact the authorized service stations!
2.
Hybrid rust protection
The water tank's inner surface is protected against corrosion by a system
consisting of two anodes: one Titanium and one Magnesium, working
independently of one another. The Titanium anode emits a low current
which provides active and permanent protection of the water tank against
corrosion, regardless of the content of the water. The Titanium anode does
not undergo wear.
In addition, the second anode protector – the Magnesium one, enhances
the protection of the water tank by dispersing magnesium particles in
the water. It protects the water tank's inner surface when the tank is not
connected to the electric mains (for example – in the event of a power
failure).
In order to ensure the long-term and breakdown-free use of your appliance,
the manufacturer recommends periodic inspections of the magnesium
anode's condition by a qualified technician and replacement whenever
required, and this could be performed during the appliance's technical
preventive maintenance
The magnesium anode undergoes wear and when the wear is more than
50% (fifty percent) the magnesium anode shall be replaced with a new one,
provided by the manufacturer.
For replacements, please contact the authorized service stations!
8
VII.
OPERATION.
Switch on.
1.
Before switching on the appliance for first time, make sure that the boiler
is properly connected to the power supply network and full with water.
The boiler is switched on by a switch integrated into the installation,
described in item 3.2 of Section V, or upon connecting the plug to the
electrical contact (in the case of an extension cable with plug).
2.
Water heaters with electromechanical control
Fig. 2 where:
1 - Moisture-proof button for heater switching (for models with a switch)
2 - Light indicator
3 - Regulator handle (only for models with adjustable thermostat)
Electrical switch with one knob:
0 – switched off;
I – switched on;
The knob lit when the switch is on.
The control lamp on the panel indicates the state (the mode) in which the
appliance is placed: it is lit when the water is being heated and is switched
off when the specified by the thermostat water temperature level is reached.
Electrical switch with two knobs:
0 - switched off; I; II - switched on.
Choosing of different power levels of heating:
Rated power (marked
Switched on
on the rating label)
knob (I)
1600 W
800 W
2400 W
1200 W
The buttons of the switch lit on, if they are switched on and during heating.
They stops to lit when the preset temperature of the water is reached and
the thermostat switch-off the voltage supply.
The control lamp lit on when there is supply voltage from electrical main.
It does not lit on when there is not supply voltage or the thermal cut-out
(temperature protection) is switched off (see 3 below).
For models without a switch
The control lamp on the panel indicates the state (the mode) in which
the appliance is placed: it is lit when the water is being heated and is
switched off when the specified by the thermostat water temperature level
is reached.
It does not lit on when there is not supply voltage or the thermal cut-out
(temperature protection) is switched off (see 4 below).
Temperature setup (for models with adjustable thermostat).
This setup allows the gradual setting of the desired temperature, achieved
by using a handle on the control panel.
e
Position
(Energy-save mode) – At this mode, water temperature reaches
up to approximately 60°С. Heat losses are reduced in this way.
Fig. 2 indicates the direction of rotation of the knob for the other models with
externally adjustable thermostat.
Attention! Place the thermostat knob in position for maximum
temperature (unless it is on this position constantly), for period of one
day each month. This ensures higher hygiene of the used hot water.
3.
Models with hybrid rust protection
Fig. 2 where:
1 - Moisture-proof button for heater switching (for models with a switch)
2 - Light indicator
3 - Regulator handle (only for models with adjustable thermostat)
Electrical switch with two knobs:
0 - switched off; I; II - switched on.
Choosing of different power levels of heating:
Rated power (marked
Switched on
on the rating label)
knob (I)
2400 W
1200 W
The buttons of the switch lit on, if they are switched on and during heating.
They stops to lit when the preset temperature of the water is reached and
the thermostat switch-off the voltage supply.
Light indicator
Legend:
- brief red flash
- brief green flash
▀▀▀
- long red flash
. . . . .
- pause
Switched on
Switched on
knob (II)
knob I and II
800 W
1600 W
1200 W
2400 W
Switched on
Switched on
knob (II)
knob I and II
1200 W
2400 W