INSTALLATION MANUAL
KCPROXWLC
Dual Technology Digicode
3] MOUNTING KIT
KCPROXWLC
4] MOUNTING INSTRUCTIONS
1
Place the back plate on the
wall then mark with a pen
the hole location then drill
the 2 mounting holes and
the hole wiring access.
5] WIRING EXAMPLE: KCPROXWLC TO A CONTROLLER
KCPROXWLC WIRING TABLE
Wiegand format
Cables
outputs
RED
12VDC Input
BLACK
0V
Buzzer command
BROWN
input
GREEN
DATA 0
WHITE
DATA 1
BLUE
CLOCK
PURPLE
PROGRAMMING
YELLOW
GREEN LED
ORANGE
RED LED
/Proximity reader
®
M5x8 Diax
T20 Diax
®
screw
1
2
Insert the 2 plastic anchors
in the holes.
Mount the back plate
of the KCPROXWLC with the
screw on the wall.
ISO2 format
Standard format
Outputs
Outputs
12VDC Input
12VDC Input
0V
0V
Buzzer command
Buzzer command
input
input
CODE
DATA
CLOCK
STANDARD – 1 WIRE
PROGRAMMING
PROGRAMMING
GREEN LED
GREEN LED
RED LED
RED LED
®
Spanner
anchor
1
3
Insert the cable in the hole
access area of the back
plate. Then mount the
keypad on the back plate.
Controller terminal wirings
CTV900A
(CENTAUR)
+12V
R1/0V
R2/0V
OUT5
OUT6
R1/D0
R2/D0
R1/D1
R2/D1
OUT1
OUT3
OUT2
OUT4
Plastic
M4x30 screw
2
4
Fasten the KCPROXWLC
keypad to the back plate
with the M5x8 Diax
and T20 Diax
hardware.
ONLINE SYSTEMS
AC22
INTBUSW
(ATRIUM)
+12V
GND
BUZ
D0
D1
GRN
RED
cdvi.com
cdvigroup.com
EN
2
screw
®
spanner
®
12
V
7
1
3
2*
8
9
* Optional
17