INSTALLATION

CAUTION
We strongly recommend the removal of the
old wall sleeve and the installation of a new
Kenmore folding Wall Sleeve.
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of the
wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or product failure.
This is not covered under the terms of the
Kenmore warranty.
• Pick a location which will allow the conditioned air to
blow into the area you want. Good installation with
special attention to the proper position of the unit will
lessen the chance that service will be needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused
parts
ITEM (inches)
Plastic grille
Horizontal Insulation Strips 1
Around Insulation Strips
Support Block
Baffle
Shim
Trim Frame
Washer Screw
Nuts(Plastic)
Grille Rear

HOW TO INSTALL

1
Identify the existing wall sleeve before installing
the unit from the listed below.
Wall Sleeve Dimensions (inches)
Brand
White-Westinghouse
Frigidaire
Carrier (52F series)
General Electric
/Hotpoint
Whirlpool
Fedders/Emerson
Sears/Kenmore
Emerson/Fedders
Carrier (51S Series)
Friedrich
INSTALLATION
26
3 / 4
x 16
1 / 2
x
x 27
3 / 8
5 / 8
3 / 16
1
3 / 8
x 1
3 / 8
x 27
3 / 16
1
3 /
x
3 /
x 61
1 /
8
4
2
1
3 / 8
x 1
3 / 8
x 61
1 / 2
1
3 / 4
x 1
3 / 8
x 4
5 / 16
14 x 4
x
1 / 2
1 / 8
13 x 1 x
3 /
4
Width
Height
Depth
16, 17-1/2
25-1/2
15-1/4
or 22
26
15-5/8
16-7/8
17-1/8
25-7/8
16-1/2
or 23
16-3/4
27
16-3/4
or 19-3/4
25-7/8 15-17/32 16-23/32
26-3/4
15-3/4
15
25-3/4
16-7/8
18-5/8
27
16-3/4
16-3/4
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition
and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the
Air Conditioner,
Remove old air conditioner from existing wall
2
sleeve.
Clean the interior of an existing sleeve.
3
(Do not disturb seals.)
Wall sleeve must be securely fastened in wall
4
before installing the air conditioner. Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
Prepare the wall sleeve for installation of the
5
unit. If you plan to use your existing wall sleeve,
and it is not Kenmore, use procedure B or C
below.
Procedure
Brand
A
Sears/Kenmore
White-Westinghouse
Frigidaire Carrier
Qty.
(52F series)
1
General Electric
B
1
/Hotpoint
1
Whirlpool
1
Carrier (51S series)
1
2
Fedders/Emerson
1
C
Emerson/Fedders
2
Friedrich
2
4
6
4
Install new unit into wall sleeve.
1
CAUTION: When installation is completed,
replacement unit MUST have a rearward slope as
shown. To achieve 1/4" slope, remove the backing
from the 13" shim strips and attach them as shown
below in Fig. 2. Place the higher portion of shim to
the front of the rib on base of wall sleeve.
1" high
6"
SHIM PLACEMENT
- 6 -
Depth(inches)
16-23/32
16, 17-1/2
17-1/8 or 23
or 19-3/4
3 / 4 " High
UNIT
FRONT
Shim
1/4"
6"
UNIT INSTALLATION
or 22
16-7/8
18-5/8
16-3/4
15
16-3/4
Wall Sleeve
FIG. 2

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido