the appliance when leaking, damaged or malfunctioning. If you detect a leak in the equipment (gas smell), bring
it immediately outside, in a well-ventilated area with no flammable sources, where you can find and stop the leak.

DURING USE:

-
Always extinguish the flame before placing torch on a surface.
-
Ensure that flexible hose is not bent
-
NEVER point the flame towards containers (they should never get hot), flexible hoses (they can burn) and to
yourself or other people.
-
Do not operate the equipment in space-constrained sites.
-
The structure of the device must work on a horizontal surface
-
Use the equipment outside or in a well-ventilated place
-
Work only in a safe and clean area, away froml oily and combustible materials, and fire hazards.
-
Wear necessary equipment for eyes protection.
-
Do not wear clothes greasy dirty.
-
Avoid inhaling welding/brazing fumes.
-
It is recommended to wear protective gloves that avoid burns when handling hot materials and equipment;
allow the welded material and the components to cool down before touching or moving them to a different
location.
-
Given the possibility of projection of overheated material, it is recommended to use gowns or aprons for the
protection of the body.
-
Do not try to move the equipment by pulling the hoses.
Some instructions on how to use cylinders:
Cylinders are pressure containers of flammable material and special attention needs to be paid when using them,
in particular:
-
Do not expose to direct sun rays and temperatures over 50°C.
-
Do not pierce or burn after use
-
Discard only when completely empty
-
Do not spray over hot or incandescent material.
-
The oxygen cylinders 571 and 570 are disposable units, so DO NOT refill them.
-
The oxygen cylinder 585H200 is rechargeable. It must therefore be recharged only by the supplier; filling done
differently can lead to serious accidents.

EXTINGUISHING THE FLAME:

For temporary interruptions of work:
-
To extinguish the flame, always close the gas stopcock first, then close the oxygen stopcock located on the
torch grip.
-
Do not maintain the pipes under pressure
-
Allow the torch to cool down before touching it or placing it on a surface; always place the nozzle on
appropriate non-flammable stand.
For storing the equipment for a long time:
-
To stop gas flow, close the screw located on the gas cylinder inlet valve.
-
Close the gas stopcock located on the torch grip.
-
Close the oxygen stopcock
-
Disconnect containers
-
Maintain cylinders always in vertical position

STORAGE AND TRANSPORT CONDITIONS

-
Disconnect containers if the equipment is not used for a long time period or in case of transport with vehicle.
-
Ensure containers are always in a vertical position during storage and transport operations.
-
Keep away from children
MAINTENANCE
-
Use only original replacement parts
-
Never use the equipment if any components appear damaged
-
IMPORTANT NOTE: do not carry out any type of operations on single parts of the appliance; it may result in
serious risks for the user. If the equipment does not function properly, contact your local sale representative or
KEMPER's support service – Via Prampolini 1/Q – 43044 Lemignano di Collecchio (PR) – Tel +39 0521 957111 –
Fax +39 0521 957195
-
Carefully follow instructions provided during maintenance operations.