CUADRO CONTROL RELAI - ESTUFA DESLIZABL E
VOLTAJES AC
Relai Tablero Enrg Principal
MODO DE SERVICIO
ON=120VAC (L1-N or L2-N)
or 240VAC (L1-L2)
Función
L2 = J4-8 (K1-NO)
Ventilador Enfr. Derecho
..................................................................................................................................................................
Vent Enfr D -> On/Off
Ventiladores Enfr. Izq.
L2 = J4-7 (K5-NO)
Agitador Mag
Ventilador Mag
..................................................................................................................................................................
Ventilador HVT
Vents Enfr I -> On/Off
L1 = J4-5 (K13-NO)
..................................................................................................................................................................
LUZ DEL HORNO
Luz del Horno -> On/Off
HVT T2 = L2 = J107 (K9-NO)
HVT T3 = L2 = J105 (K9-NC)
Microonda
Cargas Cocina -> MW
..................................................................................................................................................................
HVT T1 = L1 = J114
L2 = J4-9 (K106-NO)
Ventilador Respirador
..................................................................................................................................................................
Vent Respirador -> On/Off
L1 = K10-NO
Elemento Convección
..................................................................................................................................................................
Cargas Cocina -> ConvElem
L2 = K102-NO (DLB)
L1 = J4-2 (K105-NC)
Ventilador Convección
Derecha
..................................................................................................................................................................
Cargas Cocina
-> Vent Conv -> CW
Ventilador Convección
L1 = J4-3 (K105-NO)
Derecha
..................................................................................................................................................................
Cargas Cocina
-> Vent Conv -> CCW
Alemento Asar
..................................................................................................................................................................
Cargas Cocina -> Asar
L2 = K11-COM (DLB)
Elemento Hornear
..................................................................................................................................................................
Cargas Cocina -> Hornear
L2 = K11-COM (DLB)
L1 = J113 (K103-NO)
Elemento Hornear2
..................................................................................................................................................................
Cargas Cocina-> Hornear2
L2 = K11-COM (DLB)
L1 = J4-1 (K2-COM)
Aldaba Puerta
..................................................................................................................................................................
Aldaba Puerta -> Cerrada/Abierta
Nota: Referencia a tierra para medidas de voltaje dc
es J3-2 ó J3-4 en MPB ó J5-2 ó J5-4 en MLB
Control Relai
ON = 0Vdc
OFF = 12Vdc
OFF=0V
MPB J1-10
MLB J3-10
N = J103
MPB J1-9
MLB J3-9
N = J103
MPB J1-4
MLB J3-4
N = J103
O
MPB J1-3
MLB J3-3
N = J103
MPB J1-16 OFF
MLB J3-16 OFF
N = J103
MPB J1-16
MLB J3-16
N = J103
L1 = K7-NO
L1 = K8-NO
MPB J1-18
MLB J3-18
MPB J1-14
MLB J3-14
N = J103
MPB = Tablero Energía Principal
MLB = Tablero Lógico Principal
VOLTAJES DC
Control Relai
Habiliado = 4.2Vdc
ON = 4.6Vdc
Inhabilitado = -14.0Vdc
OFF = -14Vdc *
MPB J1-17
MLB J3-17
MPB J1-1
OR
MLB J3-1
MPB J1-17 OFF
MLB J3-17 OFF
MPB J1-8
MPB J1-1
MLB J3-8
MLB J3-1
MPB J1-12
MLB J3-12
MPB J1-6
MPB J1-1
MLB J3-6
MLB J3-1
MPB J1-11
MLB J3-11
MPB J1-7
MPB J1-1
MLB J3-7
MLB J3-1
MPB J1-11
MLB J3-11
MPB J1-1
MLB J3-1
MPB J1-11
MLB J3-11
* OFF = 0Vdc si Inhabilitado = -14Vdc
– 36 –
Notas
Ventilador se enciende cuando se entra
al menú de cargas de cocina.
Ventilador se enciende cuando se entra
al menú de cargas de cocina.
K6 (Relai Princ Mag) debe ser energizado
MPB J1-5 ON (4.6Vdc)
MLB J3-5 ON (4.6Vdc)
Nota: Mag Tap es seleccionado auto-
máticamente por el Voltaje de la Línea.
Ventilador se enciende cuando se entra
al menú de cargas de cocina.
K4 (Relai Ventilador Convección)
debe ser energizado.
MPB J1115 ON (0Vdc)
MLB J3-15 ON (0Vdc)
K4 (Relai Ventilador Convección)
debe ser energizado.
MPB J1-15 ON (0Vdc)
MLB J3-15 ON (0Vdc)
Elemento de asar debe ser apagado.
Elemento de asar debe ser apagado.