Troubleshooting

If the appliance does not work, before calling for Assistance (see Assistance), check for a solution from the following
list.
Malfunctions:
The internal light does not
illuminate.
The refrigerator do not cool well.
The food inside the refrigerator is
beginning to freeze.
The motor runs continuously.
The appliance makes a lot of noise.
There is water at the bottom of the
refrigerator.
Possible causes / Solutions:
• The plug has not been inserted into the electrical socket, or not far
enough to make contact, or there is no power in the house.
• The doors do not close properly or the seals are damaged.
• The doors are opened too frequently.
• The TEMPERATURE ADJUSTMENT knob is not in the correct position
• The refrigerator have been over-filled.
• The TEMPERATURE ADJUSTMENT knob is not in the correct
position.
• The door is not closed properly or is continuously opened.
• The outside ambient temperature is very high.
• The thickness of the frost exceeds 2-3 mm (see Maintenance).
• The appliance has not been installed on a level surface (see
Installation).
• The appliance has been installed between cabinets that vibrate and
make noise.
• The internal refrigerant makes a slight noise even when the
compressor is off. This is not a defect, it is normal.
• The water discharge hole is blocked (see Maintenance).