• Absence list
Display of currently absent persons.
This function is only possible if there
are output readers configured at the
TCIP 603-...
Tools
• Password
Changing the password for the user
currently logged in.
• Alarms/status messages
Display of alarm and/or status mes
sages.
• Direct actuation of the door
release
Actuation of connected door
releases via the program user inter
face.
• Memory utilization
Display of available doors, time pro
files, access groups, users and public
holidays.
Procedure when commissioning
with read modules
• Select the TCIP 603-... with an
Internet browser http://192.168.0.1
• Enter the user name Service and
password Siedle. (case sensitive).
• Read in the connected input
modules
• Designate names for the entered
input modules
• Assign inputs/outputs
• Generate a time profile
• Create entrance doors
• Generate access groups
• Create users
TCIP 603-... data backup
The enclosed CD contains the file
TCIP603Backup.exe, which is used
to save the configuration of a
TCIP 603-... on PC.
Restoring the as-delivered status
in the TCIP 603-...
When the operating voltage is
switched off, insert the battery
plate for around 10 seconds and
remove again. All the saved values
are deleted.
Specifications
Operating voltage: 20–30 V DC
Operating current: max. 700 mA
Contact type: n.o. contact
15 V AC/30 V DC, 2 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Dimensions (mm) W x H x D:
131 x 111 x 52
System documentation
IP address
___.___.___.___
Subnet mask ___.___.___.___
Gateway
___.___.___.___
Connected modules (tick as appro
priate)
FSM 740-...
SCE 640-...
Entrance/door 1
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 2
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 3
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 4
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 5
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 6
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 7
COM 611-...
ELM 611-...
FPM 611-...
Entrance/door 8
COM 611-...
ELM 611-...
FPM 611-...
11