Motor power (to increase the power turn the trimmer clockwise)
INTENSITY OF USE:
the control unit limits the intensity of use of the gate for breaks of less than 120 seconds. On reaching the 12th opening the gate remains still for 120 seconds,
in this time the control buttons, remote controls and the automatic closing function are not active.
The phase of stoppage is signalled by 3 blinks of the flashing light when a command is sent. At the end of the stoppage time the gate returns to normal op-
eration.
ELECTRONIC CLUTCH MANAGEMENT
The electronic clutch is always active in both directions, when it trips during opening, the gate reverses for approximately 2 sec., while during closing it stops
and opens completely. If it trips for 4 consecutive times the entire system STOPS and disables automatic closing, when applicable, forcing the user to give a
start pulse and the gate performs a complete manoeuvre at slowdown speed.
9 - Installing batteries
The battery charger is integrated in the control unit and enables charging 2 12 V lead-acid batteries with a capacity of 1.5 Ah. The charging system is protected
against short circuits. Place the batteries in the dedicated compartment and connect the 2 batteries in series, respecting the polarities, see image.