INSTALLATION
INSTALL SUCTION WEIGHT TO SUCTION LINE
1. Drill a hole into the bung cap or solution tank lid. Slide the tubing through and secure
the weighted strainer to the line.
2. To attach the strainer, push approximately 3.5" of suction line through the cap on the
strainer body. Pull tubing to make sure it is secure.
3. Suspend slightly above tank bottom to reduce the chance of sediment pickup.
DO NOT mix chemicals in the solution container. Follow recommended mixing
procedures according to the manufacturer.
DO NOT operate pump unless chemical is completely in solution. Turn pump off
when replenishing solution.
3.5"
(9 cm)
continued
US and Canada 800.683.2378, International 904.641.1666
Suction Line
Weighted
Suction Line
Strainer
3
"
17