OUTPUT AND SIZING CHARTS
OUTPUTS
MAXIMUM
MODEL
PRESSURE
M05
25 psi (1.7 bar)
*
M07
100 psi (6.9 bar)
SIZING FOR 1:128 DOSING
MAXIMUM
MODEL
PRESSURE
M05
25 psi (1.7 bar)
*
M07
100 psi (6.9 bar)
NOTE: To inject at a ratio of 1:128 at flow rates higher that 3.5 gpm up to 100 psi, the injection point can be installed
after a pressure regulator. This will allow flow rates up to 8.4 gpm up to 25 psi.
*
Injection check valve included with pumps rated 26-100 psi (1.8-6.9 bar).
ALTERNATIVE SIZING FOR M07 MODEL USING 1 PULSE/GALLON METER
DOSAGE
DOSAGE
OZ/GAL
RATIO
1.0
1:128
0.50
1:256
0.25
1:512
NOTE: 1oz =29.57 ml; 1 gallon =3.78 liters
NOTICE: The information within these charts is solely intended for use as a guide. The output data is an approximation based
on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
PUMP TUBE
Gallons
NUMBER
per Day per Day per Hour per Hour per Minute per Minute
#5
95.0
#7
40.0
PUMP TUBE
Max. Output @ 50/60 Hz Max. System Water Flow for 1:128 Dosing
NUMBER
oz/min
#5
#7
MAX. SYSTEM WATER FLOW
gal/min
3.5
7.0
14.0
US and Canada 800.683.2378, International 904.641.1666
APPROXIMATE MAXIMUM OUTPUT@ 50/60Hz
Liters
Gallons
359.6
3.96
151.4
1.67
ml/min
8.4
249.7
3.5
105.1
PULSE SETTING
Liters
Ounces
14.98
8.44
6.31
3.55
gal/min
L/min
8.4
31.8
3.5
13.2
1
2
4
Milliliters
249.73
105.14
7