Elpro S40
GB
FUNCTIONS
Automatic / semi-automatic:
Automatic cycle: after an opening pulse, the bollard goes down, it stops for dwell time pre-set in trimmer
T2, after the pre-set time it closes automatically.
Semi-automatic: after an opening pulse, the bollard goes down. A closing pulse is needed to close.
Pedestrian opening:
This command is separate from the standard opening command. When all the
posts are in up position, on pulsing input P dip-switch 6 = ON and 3 = ON, post
n° 1 (motor M1) goes down for pedestrian opening, for the time pre-set in Trimmer
T2, after this time it closes automatically. The function pedestrian opening is not
in service during the rst operation cycle, after a power failure.
Hold on switched (deadman) control:
Open and close operations are achieved by holding a switch on (no relay self-holding
is involved) therefore a physical attendance is required to keep the post opening or
closing until either the button or key is released.
External clock (optional):
The electronic programmer Elpro S40 can be connected to a clock
for the post opening and closing.
Connection: connect in parallel the NO clock contact to the 4 OPEN
and 3 COMMON terminals, automatic closing is by dip-switch
n° 3 = ON.
How it works: program the opening time on the clock. At the preset
time, the post goes down and remain open (the ashing light will
turn o ) and will not accept any other command (not even radio
commands) until the time set on the clock expires. When this time
expires the gates close automatically after the pause time. While the
posts are held open by the time set on the clock, the indication light
keeps giving out two consecutive ashes followed by a long pause.
Plug-in tra c lights interface (optional - code 7282L):
The interface power supply (230 V - 50 Hz 100 W output per lamp) is independent from the one
of the programmer.
It can work also with the 2 lamps, red and green tra c lights (dip-switch 8 = OFF and 9 = OFF)
Working logic:
- GREEN light = post in down position, OPEN passage
- RED light = moving post or in up position, CLOSED passage
- YELLOW light = it lights before the switching from the green light to the red light.
Note: during pedestrian mode the tra c light is always RED.
63
64 65 66 60 61
(Optional: plug-in PCB
for 230V tra c lights) code 7282L
ELECTRONIC CONTROLLER UP TO 4 AUTOMATIC BOLLARDS,
WITH OR WITHOUT LIMIT SWITCH
Description
RED
YELLOW
GREEN
Fuse 1 A
Red
Yellow
Green
57 58
External clock
3 4
NO
13
Dip-switch setting and LED indication of functions
DIP-SWITCH N° 3:
ON: automatic closing
OFF: no automatic closing.
3
Semi-automatic function
Dwell time: from 1 to 180 s
T2
DIP-SWITCH N° 3 and N° 6 both on ON:
ON: automatic closing
OFF: No automatic closing.
3
Semi-automatic closing
ON: pedestrian opening motor M1
6
OFF: standard operation
Dwell time: from 1 to 180 s
T2
DIP-SWITCH N° 7:
ON: deadman control
6
OFF: standard operations
DIP-SWITCH N° 3:
ON: automatic closing
OFF: No automatic closing.
3
Semi-automatic function
Trimmer pausa: da 1 s no a 180 s
T2
DIP-SWITCHES:
Dip-switch 8 = ON and 9 = ON
ON
ON
The yellow light turns on for the time
of 10 s after the red light turns on and
8
9
after 7 s the post starts rising
Dip-switch 8 = OFF and 9 = OFF
The yellow light turns on for the time
OFF
OFF
of 0 s and after 0 s the red light turns
8
9
on and the post starts rising
immediately
Dip-switch 8 = ON and 9 = OFF
ON
The yellow light turns on for the time
OFF
of 2 s after the red light turns on and
8
9
after 2 s the post starts rising
Dip-switch 8 = OFF and 9 = ON
ON
The yellow light turns on for the time
OFF
of 6 s after the red light turns on and
8
9
after 5 s the post starts rising