This appliance is intended for use on an electricity network of 230V with an alternative current of 50Hz, and
requires a cable protected by a 32A fuse, with a 6mm2 cable section.
Before connecting, ensure that the power of your electrical system is sufficient to enable your appliance to
function safely.
In case of any doubt, contact your installer; the electrical connection must be in compliance with EN60335
regulations.
The inlet cable section is very important, and must be sufficient to prevent overheating and the risk of fire in
your home.
CAUTION: This appliance must be grounded through an appropriate outlet.
This outlet must be connected to a connector in compliance with regulations in place at the time of the
installation.
CAUTION: In all cases, the power cable must be positioned such that it is not in direct contact with any hot
surfaces. At no time should the temperature around the cable exceed 50ºC
CAUTION: Position your appliance close to the power supply to prevent the power cable from being
overstretched.
NOTE: It is recommended that these steps are carried out by a certified specialist.
1. To connect, open the terminal block by inserting a screwdriver into the tabs at the sides of the cover.
Using the screwdriver as a lever, push downwards to open the cover as shown below:
2. Connect the cables following the diagram on the inside of the terminal block cover, or refer to the
connection diagram section (below).
3. Secure the power cable firmly and close the terminal block cover.