Descargar Imprimir esta página

Broan-NuTone 744LED Instrucciones

Ventilador con lámpara empotrado

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Models 744LED / 744LEDNT Recessed Fan / Light
Register this product at www.broan.com/register. For Warranty
Statement, or to order Service Parts: go to www.broan.com or www.
nutone.com and type the Model in the "Model Search" field at the top of
the page. Broan, 926 W. State Street, Hartford, WI 53027 800-637-1453
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. Install this unit in a flat ceiling only.
10. For use in non fire rated installations only.
11. Not for use in environmental air handling spaces.
12. CAUTION - RISK OF FIRE AND PERSONAL INJURY: 75W
MAX. LAMP. Use R30, BR30, PAR30L, or PAR30LN lamps only
(75W Max.). For wet locations (tub or shower) - use PAR30L or
PAR30LN (75W Max.) lamp only. Use no other lamp types. Do
not install a lamp indentified for use only in enclosed luminaries.
13. Do not install in a ceiling thermally insulated to a value greater
than R60.
14. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, use the cardboard protector (provided) to keep drywall
spray, construction dust, etc. off power unit.
3. The LED bulb used with this product twists into the bulb socket.
Do not attempt to insert or remove bulb by pushing it straight
in or pulling it straight down.
4. Please read specification label on product for further information
and requirements.
OPERATION
The fan and light can be operated using various combinations of
on/off switches and controls:
• Fan and light controlled with single on/off switch
• Fan and light controlled with separate on/off switches
• Fan controlled with timer control
• Fan controlled with speed control
See "Connect Wiring" section for various wiring options.
CLEANING
To clean trim ring / baffle: Vacuum with a soft brush attachment or
remove trim ring / baffle and clean with a soft cloth and mild soap
or detergent. Dry thoroughly before reinstalling.
To clean inside of housing: Remove trim ring / baffle and vacuum
inside of housing with a soft brush attachment.
MAINTENANCE
Motor is permanently lubricated. Do not oil or disassemble motor.
See "Service Parts" section for a list and illustrations of service parts.
PLAN THE INSTALLATION
The unit can
POWER
be installed
CABLE
4" ROUND
DAMPER/DUCT
anywhere
CONNECTOR
between ceiling
joists using
CEILING
mounting
JOIST
brackets
provided.
*
Install in a flat
ceiling only.
FINISHED CEILING
ROOF CAP
**
4-IN. ROUND
DUCT **
4-IN. ROUND
ELBOW
**
Two of the most common ways to connect ductwork to the unit.
The unit will operate most quietly and efficiently when located where
the shortest possible duct run and minimum number of elbows will
be needed.
Plan to supply the unit with proper line voltage and appropriate
power cable.
The unit must not
be installed above or
inside the cooking
area shown.
INSTALLATION
CARDBOARD PROTECTOR
1. Install mounting brackets.
Slide the adjustable mounting brackets into the bracket channels
on the housing.
Bend the tabs on the cardboard protector and insert protector into
opening in housing.
NOTE: The cardboard protector shields the inside of the housing
from drywall spray and construction dust. Do not remove it until
after construction is completed.
2. Mark mounting location.
Position unit between joists and extend mounting brackets.
IMPORTANT: Position brackets so there will be an 1/8" gap
between bottom of housing and ceiling material. Mark the top of
keyhole slot on all four mounting brackets.
3. Pound in nails.
Remove unit temporarily, and pound
nails partially into joists at all four
marked locations.
4. Hang and secure housing.
Hang unit from nails. Check to make
sure that there will be a 1/8" gap
between bottom of housing and
ceiling material. Pound nails tight.
For wide joist centers: A #8 x 3/8
self-tapping screw can be used to
join extended brackets together and
create a rigid mount. To ensure a
noise-free mount, crimp the bracket
channels tightly around mounting
brackets.
Typical Installation
HOUSING
MOUNTING
BRACKET
5. Attach damper/duct connector.
Snap the damper/duct connector onto housing. Make sure that
tabs on the connector lock in housing slots. (Top of damper/duct
*
TRIM RING / BAFFLE
connector will be flush with top of housing.) Install ductwork.
**
Purchase separately
NOTE: Make sure damper flap is in
place inside of duct connector. If it
is not:

connector to
place.
WALL
**
CAP
COOKING AREA
Do not install above
or inside this area
45
45
Cooking
Equipment
Do not install in a cooking area.
1/8" GAP
FLUSH
Squeeze top and bottom of
snap flap back into
HORIZONTAL POWER
CABLE CONNECTION
Floor
6. Choose power cable direction.
Remove wiring plate. When re-attached, the wiring plate allows the
power cable to enter unit horizontally or vertically.
7. Connect wiring.
Unit can be wired from outside of housing as shown. Use UL approved
connectors to wire per local codes.
BLUE AND
BLACK
TO BLACK
WHITE
TO
WHITE
WIRING PLATE
Fan and Light operated with single on/off switch
BLUE (FAN)
TO
BLACK
WHITE
TO
WHITE
WIRING PLATE
Fan operated with separate on/off switch,
Light operated with separate on/off switch.
FINISHED
CEILING
MATERIAL
CLEARANCE
HOLE
8. Finish ceiling.
Cut an opening in finished ceiling material for housing collar.
SPRINGS
LAMP
BRACKET
9. Attach trim ring / baffle to housing.
Remove the cardboard protector from inside the housing collar.
Use a pencil to insert one end of each spring into the holes on the
lamp bracket. Center trim ring / baffle in ceiling opening.
10. Install bulb.
CAUTION - RISK OF FIRE: Use only R30, BR30, or PAR30
shaped, 10W LED bulb with GU24 base (supplied).
Replacement bulbs can be ordered from Broan if not
available locally (see service parts list).
!
CAUTION: Twist bulb to install or remove.
VERTICAL
POWER CABLE
CONNECTION
TOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
2-WIRE PLUS
GROUND
POWER
CABLE
TOP / BACK
OF HOUSING
BLACK (LAMP)
TO RED
GROUND TO
WIRING PLATE
3-WIRE PLUS
GROUND
POWER
CABLE
speed control or timer.
HOUSING
COLLAR
TRIM RING / BAFFLE
1102398A

Publicidad

loading

Resumen de contenidos para Broan-NuTone 744LED

  • Página 1 COOKING AREA Models 744LED / 744LEDNT Recessed Fan / Light Do not install above Register this product at www.broan.com/register. For Warranty or inside this area Statement, or to order Service Parts: go to www.broan.com or www. nutone.com and type the Model in the “Model Search” field at the top of the page.
  • Página 2 El ventilador funcionará con más eficacia y menos ruido si se ubica en un sitio donde requiera el tramo de conductos más corto posible y un Modelos 744LED / 744LEDNT Ventilador con lámpara empotrado mínimo número de codos. Alimente la unidad con el voltaje de línea y el cable eléctrico apropiados.

Este manual también es adecuado para:

744lednt