Your power unit does not require the assembly of a muffl er. Your CVS
has the muffl er installed internally. You may however desire to exhaust
the air outside. In this case you will need to attach the exhaust adapter.
This will convert the size of the exhaust to the diameter of the central
vacuum pipe.
Refer to page 8 - Image 5
• Place the power unit in order to make the exhaust pipe as short as
possible. Exhausts should be limited to no longer than 16.5ft (5m).
• Keep in mind that you may need space on the sides of your
central unit to be able to access the dirt receptacle.
Refer to page 8 - Image 6
• Align the power unit intake fi tting to the main trunk line projecting from the
DO NOT GLUE.
wall.
Attach the exhaust pipe to the motor exhaust if
exhausting outdoors. Make sure the exhaust pipe is as short as possible.
NOTE: Mount central power unit at least 12in (30cm) from the ceiling
and any adjacent wall, at least 27.5in (70cm) from the fl oor and within 6ft
(1.8m) of an electrical outlet. Review any local regulations that may apply.
Refer to page 8 - Image 2
WARNING
Do not block the hood ventilation openings on the top of the central
power unit. Lack of ventilation will cause the motor to overheat.
WARNING
Do not locate the central power unit in a high temperature area where it
is inaccessible for example, an attic or crawl space.
For the ultimate in air control you have model ZCV920H. This model
features a True HEPA fi lter and may be included with your choice of
power unit or can be purchased from an authorized dealer/distributor.
Simply attach the true HEPA fi lter as shown.
Refer to page 8 - Image 7

SYSTEM TEST

Be certain to comply with local electrical codes and regulations. Plug
the unit into a regular electrical outlet. You are now ready to check the
installation of the unit:
• Be sure the fi lter is properly installed in the power unit.
• Be sure the dirt receptacle is properly secured to the power unit.
• Plug the hose into each inlet valve to be sure the electrical
contacts operate properly.
• Check each inlet valve for air leaks.
• Check each pipe connection for air leaks.
Refer to page 8 - Image 8
HOW TO USE CENTRAL VACUUM SYSTEM
Your central vacuum system is controlled by a switch on your hose.
Simply insert the hose into the valve and turn the switch to the on position.
This will start the power unit and the fl ow of air.
When you are fi nished, turn the switch on the hose to the off position
and remove the hose from the inlet valve. When unplugging the hose,
hold the inlet cover open for a few seconds to allow suction to decrease
thus, protecting the inlet valve seal.
Refer to page 8 - Image 8

LED INDICATIONS

- OPTIONAL DEPENDING ON MODEL
You machine may be equipped with some or all of the indicators listed below.
Refer to page 8 - Image 9
On/Off
Motor Fault
Your power unit is equipped with a multi color LED panel. This LED
panel will provide you with necessary information on your power unit's
performance, maintenance and diagnostics. Below are descriptions
of the different messages the power unit will provide.

NORMAL OPERATION

When the power unit is OFF and considered to be in standby mode the
LED button will be RED.
When the power unit is ON and in use the LED will be GREEN. When
the motor fault light is ON see further description below. When the dirt
receptacle light is ON, empty dirt receptacle and press the RESET
button, and hold for 10 seconds.
When you LCD power unit is in standby mode the four white lights on your
LCD unit will light up in sequence and alternate moving from left to right
then reversing right to left. This pattern will repeat continuously and is an
indication that your power unit is ready for use and functioning properly.
MOTOR FAULT
In the case of a blown fuse or disconnected motor wire and the power
unit is not functioning the ON/OFF button will be constantly GREEN In the
case of an over current shutdown, the ON/OFF button will be fl ashing RED,
the GREEN light will on and off rapidly and the MOTOR FAULT light will be
AMBER and turn on and off rapidly. This fault will reset automatically in
15 seconds if the low volt connection is OFF at the hose.
In the case of a continued over current and the low volt connection is
ON and the hose the ON/OFF button will constantly be RED, the GREEN
light will fl ash slowly and the MOTOR FAULT will slowly fl ash AMBER.
In the unlikely event of a bad frequency received by the power unit the
power unit will not start and the ON/OFF button will remain constantly RED.
In the case of a high line voltage received by the power unit the ON/OFF
button will alternate between RED and GREEN three times- pause briefl y
– alternate between RED and GREEN three times – long pause- and then
repeat. This will continue until the line voltage returns to the correct level.

LCD SCREEN

- OPTIONAL
Refer to page 8 - Image 8
ZCV920H
In the main screen of the LCD, the Electrolux logo will appear. This logo
may scroll from side to side to avoid the image ingraining itself onto the
LCD Display. You will see the logo when the power unit is not in use.
The button that best lines up with the Power symbol on the screen can
be used to activate the unit. Press this button to toggle the unit on/off.
The unit may also be activated from any installed inlet.
Dirt Receptacle Full
Reset
4