CEBORA S.p.A
6.1
Framework.NET installation.
In the recent systems (Vista or 7) or systems
correctely updated through Windows Update, this
software is already installed and no ulterior
operation is necessary.
In the event of use a system not updated, use the
installation file appropriated for the system,
available in the folder setup\ in the CD rom.
6.2
Updating from version 1.x.
If a Cebora Robot Analyzer previous version is
already present in the system, the VCI2 previous
driver with the new VCI3 new driver manual
substitution is necessary. For this operation
follows the instructions of the "VCI - Virtual
CAN Interface, VCI-V3 Installation Manual,
Software Version 3,2" (for information contact
the Cebora Technical Service).
7
USE.
To run the program, double click on the "Cebora
Robot Analyzer" icon on the desktop.
The first time the program runs, you will be
asked the license code (fig. 2).
fig. 2
Enter the license code typed on the USB-to-CAN
module (fig. 3) and click OK.
fig. 3
NOTE: you can use only one license at a time. If
you change the USB-to-CAN module
you must insert a new license code, by
clicking the "change license" button (fig.
4) and typing the new code.
On the screen appears of working process
chosing window (fig. 4).
3.300.125-C
fig. 4
Select the working Process according with the
Robot-Pantograph installation.
Click on OK in order to execute the "Cebora
Robot Analyzer" program.
The Main Page appears according the selected
process (figs. 8 a-b-c),
8
MAIN PAGE.
8.1
Commands.
In the top side are four buttons:
EXIT, exit the "Cebora Robot Analyzer"
program.
VIEW LOG, to view the Log page.
SAVE LOG, to save the Log report to a
file.
INFO, information for Cebora S.p.A.
addresses.
8.2
Status signaling.
In the bottom side there is the status bar, with 5
possible indications:
- Synchronized, means the PC is synchronized
with the Robot Interface;
- Waiting for synchronization, the PC is not
synchronized with the Robot Interface and is
waiting for its input/output signals complete
setup;
- Communication lost, communication PC to
Robot Interface has been interrupted;
- Initializing the device, the PC is initializing
the USB to CAN converter (USB-to-CAN
module). During this state the user interface is
freezed;
- Stopping the device, the PC is stopping the
device (USB-to-CAN module) i.e. in closing
the "Cebora Robot Analyzer" program.
This indication status are implemented in the Log
report, so that are visible in the Log Windows
(fig. 6) and in the Log file.
13
GB
04/03/2016