Location Requirements - Amana NGD5500TQ Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. A gas
dryer must be exhausted to the outdoors. See "Venting
Requirements."
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the dryer and a total weight (dryer
and load) of 200 lbs (90.7 kg). The combined weight of a
companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet kit, Part No. 279810.) Clothes may not tumble
properly and models with automatic sensor cycles may not
operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.

Location Requirements

Dryer Dimensions
43³⁄₈"
(110cm)
*26"
(66cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
18"*
(45.7 cm)
1"
(2.5 cm)
*Required spacing
15¼"
(38.74cm) 43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
A
22¾"
(57.8cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
A. Small Opening Side-Swing Door
B. Large Opening Side-Swing Door
C. Wide Opening Side-Swing Door
D. Wide Opening Hamper Door
14" max.*
(35.6 cm)
29"
1"
27¾"
5"*
1"*
(2.5 cm)
(70.5 cm)
(12.7 cm)
(73.66 cm)
(2.5 cm)
A
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
22¾"
(57.8cm)
29"
(73.66cm)
B
13¾"
(34.9cm)
29"
(73.66cm)
D
3"*
(7.6 cm)
2
48 in.
*
2
(310 cm )
*
2
24 in.
3"*
2
(155 cm )
(7.6 cm)
C
3

Publicidad

Tabla de contenido
loading

Tabla de contenido