Changing advanced parameters
In certain cases, the generator allows changing certain
special parameters that are shown on the 'D1' display:
, i.e. PILOT ARC, is the ability to set the pilot arc
current from 18A to 24A (the factory setting is 22A).
, i.e. POWER, the setting in KVA of the
available power form the line, whether from the
mains line or the generator, thus avoiding an
overload and the various protections triggering.
, i.e. FACTORY, is the reset for all the settings
that have been reset to the original factory ones; for
safety purposes, this function is confirmed by
selecting the parameter 'YES' and pressing the 'E1'
knob to confirm, at this point the generator exits the
menu and returns to the factory settings.
, i.e. Time Re-Start (s), is the time that elapses
from extinguishing of the cutting arc and the
subsequent triggering of the pilot arc if the torch
button continues to be pressed. This time should be
increased when using torch extension cords.
, i.e. GRID, is the function that allows perforated
metal or grids to be cut without arc interruption. Note:
when cutting non-perforated metal sheets of
considerable thickness it is advisable to disable this
function in order to achieve the maximum cutting
penetration.
, i.e. PostGas, is the compressed air flow time
after performing the cut. It can be increased to obtain
a greater cooling of the torch.
EBC, i.e. Electrode Breakdown Control, function
monitors the wear condition of the electrode in the
torch. When the electrode is fully worn, it triggers an
alarm AL21 indicating that the electrode and the
torch hood need replacement. It is normally active;
however, it can be disabled by selecting OFF in the
menu.
To change these parameters proceed as follows:
•
Press the button 'E1' immediately after the power
button for about 8 seconds without interruption; the
blue LED 'L5' lights up
•
Turn the 'E1' knob to select the parameter to change
•
Press the 'E1' knob to confirm the selected
parameter
•
Turn the 'E1' knob to change the value of the
selected parameter
•
Press the 'E1' knob to confirm the set value
•
Turn the 'E1' switch to select another parameter to
change or turn the knob until the 'D1' display shows
the message 'OUT'
•
Press the 'E1' knob to confirm exiting the parameter
change menu and return to the main setting menu for
the cutting current.
13 Description of alarms
AL2
AL3
Secondary rectifier module overheat
AL4
Overvoltage, undervoltage or missing phase
Torch pushbutton pressed in the course of
AL7
AL10
AL15
Internal alarm (call the service centre)
AL20
Internal alarm (call the service centre)
Check the torch spare parts for wear. It can
be disabled setting the
AL21
AL22
Page 16
Primary inverter module overheat
generator switch-on
Air pressure too low for cutting
parameter.
Press the 'E1' knob to reset.
Check the torch shield.
Press the 'E1' knob to reset.