Quick Setup - CAME MR8204 Guia De Inicio Rapido

Detector de apertura y seguridad para puertas automáticas correderas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
4
SETTINGS
(by DIP-switch)
1
Can only be used if DIP 4 is OFF.
2
Not available on MR8204. If selected, the presetting «standard» is applicable.
3
Enhanced IR-immunity which excludes EN 16005-conformity of the door system.
4
The opening relay (R1) is activated in case of detection in the radar or infrared fi eld.
standard: standard environments (factory setting)
critical environment: enhanced immunity (rain, snow, lamps...) and only 1 IR-curtain activated.
shopping street: optimized for narrow sidewalks > the opening relay (R1) is activated in case of detection in radar + IR-fi eld.
hospital: optimized for persons with reduced mobility (PRM)
+
ORANGE
5
SETUP
Step outside of the infrared fi eld before launching a setup.

QUICK SETUP

SHORT
SAFETY INSTRUCTIONS
- Test the good functioning of the installation before leaving the premises.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer
of the sensor.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to
neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
PRESETTINGS
critical
environment
standard
OFF
LONG (> 3s)
RED-GREEN
OFF
ENVIRONMENT
hospital
2
shopping
1
street
After changing a DIP-switch, the orange LED fl ashes.
A LONG push on the push button confi rms the setting.
Always launch a setup after changes of the DIP-settings.
ASSISTED SETUP
OPEN+CLOSE
LONG (> 3s)
:
TIP
Launch an ASSISTED SETUP to verify wiring, position of the
curtains and correct functioning of the sensor.
RELAY R1 ACTIVATION
motion
3
extreme
presence
standard
motion
+
RED-GREEN
OFF
or
4

Publicidad