Installation
Installation check codes
: LED ON, : LED Blink
Check code
Drying Cooling
Ins
0
C80
C90
Ct
tC
C1
dC
9C1
Check code
0
Vent condition is good.
Clg (Cg)
The vent is clogged.
About 80 % of the vent is clogged.
C80 (C8)
(This may decrease the drying
performance.)
Over 90 % of the vent is clogged.
C90 (C9)
(This may lead to poor drying
performance or cause malfunction)
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
Ct
or too high (over 104 °F (40 °C)) and
therefore, vent blockage cannot be
detected.
tC
Temperature sensor error.
The unit is detecting items inside
C1
the drum, or there is an error on the
dry sensor.
30
English
DV3000A(SEM)_DC68-03784P-00_EN.indd 30
Display
Wrinkle
End
Prevent
Meaning
Temp.
Extra
Low
Medium
High
Low
Solution
1. Clean the lint filter.
2. Check your vent condition.
(Refer to the "Ducting
requirements" section)
* You must take measures (such
as cleaning) through expert
personnel.
Leave the dryer at room
temperature (41 ~ 95 °F (5 ~ 35 °C))
for an hour and check again.
Contact a service center.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
Time (min.)
20
40
60
80
2020-12-07
4:50:56

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dveg41a3000 serieDve41a3000w

Tabla de contenido