eNet
Tecla persiana con receptor vía radio
Priority, lockout protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
Slat changeover time
Fabricstretching time
Moving time
Minimum changeovertime
Invert movement direction
Operating hours up
32582603
J:0082582603
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
0 ms ... 10 sec
300 ms ... 10 s
Basic setting: 0 ms / 300 ms
1 ... 600 sec
Basic setting: 120 s
300 ms ... 10 sec
Basic setting: 1 s
On, Off
Basic setting: Off
0...65535
Basic setting: Current value
6/8
Specifies the priority for reca
lling and removing a scene of
type Lockout protection for
the channel.
Specifies the priority for reca
lling and removing a scene of
type Forced position for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Wind alarm for the chan
nel.
Specifies the priority for reca
lling and removing a scene of
type Sun protection for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Twilight for the channel.
Absolute time for changing
over Venetian blind slats. The
fabric stretching time can also
be set here for the Awning
operating mode.
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
Minimum interruption time
when changing directions. In
creasing the minimum chan
geover time will cause less
wear on the motors.
Inverts the activation of the re
lay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is re
quired, for example, for con
trolling skylights.
The time is counted during
which the load is physically
switched on (relay contact clo
sed).
This parameter can be reset to
"0", for example after exchan
ging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.
13.03.2014